Specifications

Engineering Specification
Page 7
4.7 Notification
Notification Type
Notification Events
Description
Heat Alarm
0x04
State Idle
0x00
Issured when overheat or underheat alram removed.
Overheat detected
0x02
Issured when detect temperature is higher than set
value by Configuration parameter 5.
Underheat detected
0x06
Issured when detect temperature is lower than set
value by Configuration parameter 6.
Power Management
0x08
State Idle
0x00
Issured when replace new battery that battery power
more than 90%.
Replace battery now
0x0B
Issued when the battery power lower than 20%.
Weather Alarm
0x10
State Idle
0x00
Issured when Moisture Alarm removed.
Moisture Alarm
0x02
Issured when detect humidity is higher than 70% plus
set value by Configuration param 13.
4.8 Wake Up
Parameter
Value
Time
Min Wake Up Interval Seconds
0x000E10
3600 seconds
Max Wake Up Interval Seconds
0xEFF100
182 days
Default Wake Up Interval Seconds
0x093A80
7 days
Wake Up Interval Step Seconds
0x0000F0
240 seconds
4.9 Multilevel Sensor
4.10 Configuration
Parameter
0x01 (1)
Name
Minimum temperature change to report
Info
Trigger temperature report to lifeline.
Properties
Size
1
Min Value
0
Format
Unsigned Integer
Max Value
100
Read-only
False
Default Value
20
Altering capabilities
False
Advanced
False
Description
The check interval time is set by configuration parameter 3.
Value
Function
Sensor Type
Support Scale
Measure Range
Temperature
0x01
Celcius (C)
-10 to 65°C (+- 1°C)
Fahrenheit (F)
14 to 146°F (+- 1.8°F)
Relative Humidity
0x05
Percentage value (%)
0 to 80% RH +- 3%
Dew Point
Temperature
0x0B
Celcius (C)
-10 to 65°C (+- 1°C)
Fahrenheit (F)
14 to 146°F (+- 1.8°F)