Specifications

Engineering Specification
Page 6
Installer Icon Type
0x0C00 (ICON_TYPE_GENERIC_SENSOR_NOTIFICATION)
User Icon Type
0x0C10 (ICON_TYPE_SPECIFIC_SENSOR_NOTIFICATION_WEATHER_ALARM)
4.4 Manufacturer Specific
Parameter
Value
Manufacturer ID 1
0x03
Manufacturer ID 2
0x71
Product Type ID 1
0x00(EU), 0x01(US), 0x02(AU)
Product Type ID 2
0x02(PRODUCT_TYPE_ID_SENSOR)
Product ID 1
0x00
Product ID 2
0x09
4.5 Version
Parameter
Value
Z-Wave Protocol Library Type
0x03
Z-Wave Protocol Version
0x07
Z-Wave Protocol Sub Version
0x15
Firmware 0 Version
0x02
Firmware 0 Sub Version
0x00
Hardware Version
0x01
Number of firmware targets
0x00
4.6 Association Group Info
Root device
ID
Name
Node
count
Profile
Function
1
Lifeline
5
General:
Lifeline
(0x0001)
Device Reset Locally Notification:
Issued when Factory Reset is performed.
Battery Report
Issued when the battery power changes by more than 10%.
Sensor Binary Report
Issued when Mould danger alarm.
Multilevel Sensor Report
Issued when button pressed to wake up or auto report enable or detect
temperature/humidity change exceeds the set value.
Notification Report
Details see 4.7.
2
Temperature
High Trigger
5
General:
Notification
(0x7104)
Basic Set
Issured when the temperature detected is higher than set value by
Configuration parameter 5.
3
Temperature Low
Trigger
5
General:
Notification
(0x7104)
Basic Set
Issured when the temperature detected is lower than set value by
Configuration parameter 6.
4
Humidity High
Trigger
5
General:
Notification
(0x7110)
Basic Set
Issured when the humidity detected is higher than set value by
Configuration parameter 7.
5
Humidity Low
Trigger
5
General:
Notification
(0x7110)
Basic Set
Issured when the humidity detected is lower than set value by
Configuration parameter 8.
6
Air Temperature
5
General:
Sensor(0x3
101)
Multilevel Sensor Report
Sensor type = Temperature
Issured when nodes are associated in Association Group 6.