Specifications

Engineering Specification
Page 12
Format
Unsigned Integer
Max Value
255
Read-only
False
Default Value
15
Altering capabilities
False
Advanced
False
Description
Value
Function
1~255
1~255 minutes
Parameter
0x40 (64)
Name
Temperature Scale
Info
Set the temperature scale.
Properties
Size
1
Min Value
1
Format
Enumerated
Max Value
2
Read-only
False
Default Value
1(EU)/2(US)
Altering capabilities
False
Advanced
False
Description
Value
Function
1
Celsius
2
Fahrenheit
Parameter
0x41 (65)
Name
Report after include network
Info
Enable or disable report
Properties
Size
1
Min Value
0
Format
Bit field
Max Value
15
Read-only
False
Default Value
0
Altering capabilities
False
Advanced
False
Description
Value
Function
Bit0
Enable or disable battery report
Bit1
Enable or disable MULTILEVEL SENSOR REPORT
Sensor Type= Temperature
Bit2
Enable or disable MULTILEVEL SENSOR REPORT
Sensor Type= Humidity
Bit3
Enable or disable MULTILEVEL SENSOR REPORT
Sensor Type= Dew point
Parameter
0xFF (255)
Name
Reset Parameter
Info
Reset device to factory defaults.
Properties
Size
4
Min Value
0
Format
Unsigned Integer
Max Value
4294967295
Read-only
False
Default Value
0
Altering capabilities
False
Advanced
False
Description
Value
Function
0
-