Specifications
Engineering Specification
Page 10
Description
Value
Function
0
Disable
1~90
1%~90%
Parameter
0x09 (9)
Name
Low Temperature Trigger BASIC Set Send
Info
Set BASIC Set value send to Group3.
Properties
Size
1
Min Value
0
Format
Unsigned Integer
Max Value
255
Read-only
False
Default Value
255
Altering capabilities
False
Advanced
False
Description
Value
Function
0~255
Basic Set Value
Parameter
0x0A (10)
Name
High Temperature Trigger BASIC Set Send
Info
Set BASIC Set value send to Group2.
Properties
Size
1
Min Value
0
Format
Unsigned Integer
Max Value
255
Read-only
False
Default Value
0
Altering capabilities
False
Advanced
False
Description
Value
Function
0~255
Basic Set Value
Parameter
0x0B (11)
Name
Low Humidity Trigger BASIC Set Send
Info
Set BASIC Set value send to Group5.
Properties
Size
1
Min Value
0
Format
Unsigned Integer
Max Value
255
Read-only
False
Default Value
255
Altering capabilities
False
Advanced
False
Description
Value
Function
0~255
Basic Set Value
Parameter
0x0C (12)
Name
High Humidity Trigger BASIC Set Send
Info
Set BASIC Set value send to Group4.