Specifications
Engineering Specification
Page 8
0
Disable
1~100
0.1~10 degree
Parameter
0x02 (2)
Name
Minimum humidity change to report
Info
Trigger humidity report to lifeline.
Properties
Size
1
Min Value
0
Format
Unsigned Integer
Max Value
20
Read-only
False
Default Value
5
Altering capabilities
False
Advanced
False
Description
The check interval time is set by configuration parameter 3.
Value
Function
0
Disable
1~20
1-20%
Parameter
0x03 (3)
Name
Check interval for parameter 1 and 2
Info
Set the interval time
Properties
Size
1
Min Value
1
Format
Unsigned Integer
Max Value
255
Read-only
False
Default Value
15
Altering capabilities
False
Advanced
False
Description
Value
Function
1~255
1~255 minutes
Parameter
0x04 (4)
Name
Periodic Reports
Info
Set the time to send unsolicited report.
Properties
Size
2
Min Value
0
Format
Unsigned Integer
Max Value
65535
Read-only
False
Default Value
43200
Altering capabilities
False
Advanced
False
Description
Value
Function
0
Disable
30~65535
Seconds
Parameter
0x05 (5)
Name
Temperature Upper Watermark value
Info
Surpasses value send BASIC Set to Group2.