4.9 Binary Sensor
Sensor Type
Sensor Value
Description
Water
0x06
0xFF
Water leakage Detected
Water
0x06
0x00
Water leakage does not detect
4.10 Multilevel Sensor
4.11 Wake Up
Parameter Value
Time
Min Wake Up Interval Seconds 0x000E10
3600s [1 hour]
Max Wake Up Interval Seconds 0xEFF100
15724800s
Default Wake Up Interval Seconds 0x093A80
604800s [1 week]
Wake Up Interval Step Seconds 0x0000F0
240s [4 minutes]
4.12 Battery
1. The 2.90V or more battery voltage corresponds to 100% battery level, and 2.60V or less corresponds to 0%.
2. If send Battery Get to the device, it will issue Battery Report with battery level to the requester when waked up.
3. If waked up or power on, it will detect battery level, and issue Battery Report via Lifeline when battery level change
over 10%.
4. if the battery level is less then the value of configuration parameter 23, send Battery Report 0xFF and Notification
Report of replace battery now via Lifeline .
5. If the battery level is less than the value of configuration parameter 23
, LED will flash red 3 times for each waked up.
4.13 Indicator
Indicator ID
Property ID
Node Identify
(Green Led)
0x50
On Off Period
0x03
On Off Cycles
0x04
On time within an On/Off period
0x05
Sensor Type Support Scale Measure Range
Temperature 0x01
Celcius (°C) -10 to 65°C (+- 1° C)
Fahrenheit (°F) 14 to 146°F (+- 1.8°F)
Relative Humidity 0x05 Percentage value (%) 0 to 80% RH +- 3%