User's Manual

AEO T EC U ser M anu a l
Page 9
Product ID 1
0x00
Product ID 2
0x0C
4.6 Version
Parameter
Value
Z-Wave Protocol Library Type
0x03
Z-Wave Protocol Version
0x07
Z-Wave Protocol Sub Version
0x0C
Firmware 0 Version
0x01 [Z-Wave Chip Firmware Version]
Firmware 0 Sub Version
0x00 [Z-Wave Chip Firmware Sub Version]
Hardware Version
0x01
Number of firmware targets
0x00
4.7 Association Group Info
Root product
ID
Name
Node count
Profile
Function
1
Lifeline
5
General: Lifeline
(0x0001)
Product Reset Locally Notification:
Issued when Factory Reset is performed.
Battery Report:
Issued when battery becomes low.
Sensor Binary Report:
Issued when tilt angle is changed
Issued when sensor state is changed.
Notification Report [Type=0x06; Event=0x16]:
Issued when sensor state is changed to be Open Status.
Notification Report [Type=0x06; Event=0x17]:
Issued when sensor state is changed to be Close Status.
Notification Report [Type=0x07; Event=0x03]:
Issued when tamper is tripped
Central Scene Notification:
Issued when the external dry contact is activated
2
Control
5
Control: Key01
(0x2001)
Basic Set:
Control devices when a magnet or external dry contacts trips
3
Alarm
5
Notification:Access
Control (0x7106)
Notification Report:
Sends out alarm message when a magnet or external dry sensor
trips
4
Tamper
5
Notification:home
Security (0x7107)
Notification Report:
Sends alarm messages when tamper is tripped
5
Tilting
5
Control: Key02
(0x2002)
Basic Set:
Control devices when tilting sensor trips
4.8 Notification
Notification Type
Notification Events
Description
Access Control
0x06
Window/Door is open
0x16
Open Status.
Window/Door is closed
0x17
Close Status.
Home Security
0x07
Tamper Removed
0x03
Tamper removed
0x00
State idle
0x00
Going to idle
4.9 Binary Sensor
Sensor Type
Sensor Value
Description
Door/Window
0x0A
0x00 / 0xFF
Door/Window State