User's Manual
Advanced functions.
Changing batteries.
Removing your MultiSensor from a Z-Wave network.
Monitoring motion.
Waking up your Multisensor.
Resetting your MultiSensor.
Adjusting the sensitivity of your MultiSensor .
 Monitoring temperature, humidity and luminance.
If you’re using a Z-Stick:
If you’re using a Minimote:
Your MultiSensor has built in battery level detection. It will automatically report its 
battery level to the associated control point throughout its life until the battery is fully 
drained and needs replacing. The battery status will often be displayed in the user 
interface of the control point.
When used properly in an optimised Z-Wave network, your MultiSensor can be 
powered by batteries for 12 months before battery replacement is necessary.
Recommendation: For networks which do not offer a method to display the battery 
level of your MultiSensor, it is recommended that the sensor be tested occasionally 
to ensure that the batteries still hold enough charge to operate. Batteries naturally 
lose their charge over time.
1. If your Z-Stick is plugged into a gateway or a computer, unplug it.
2. Take your Z-Stick to your MultiSensor.
3. Press and hold the Action Button on your Z-Stick for 3 seconds and then release.
4. Press the Z-Wave Button on your MultiSensor.
5. If your MultiSensor has been successfully removed from your network, its LED will 
blink when you press the Z-wave Button. If the removal was unsuccessful, the LED 
will stay solid for a few seconds when you press the Z-wave Button.
6. Press the Action Button on the Z-Stick to take it out of removal mode.
1. Take your Minimote to your MultiSensor.
2. Press the Remove Button on your Minimote.
3. Press the Z-wave Button on your MultiSensor.
4. If your MultiSensor has been successfully removed from your network, its LED will 
blink when you press the Z-wave Button. If the removal was unsuccessful, the LED 
will stay solid for a few seconds when you press the Z-wave Button.
5. Press any button on your Minimote to take it out of removal mode.
Your MultiSensor can be removed from your Z-Wave network at any time. You’ll 
need to use your Z-Wave network’s main controller to do this and the following 
instructions tell you how to do this using Aeotec by Aeon Labs’ Z-Stick and Minimote 
controllers. If you are using other products as your main Z-Wave controller, please 
refer to the part of their respective manuals that tells you how remove devices from 
your network.
The MultiSensor can send Basic Set Command to association group 1, which 
is setup via the Association Command Class, when the Motion Sensor detects 
movement to control the associated devices to “OPEN” state. After 4 minutes by 
default, if the Motion Sensor is not triggered again, the MultiSensor will send Basic 
Set Command to these devices to set them to their “CLOSE” state. However, if the 
Motion Sensor is triggered again within 4 minutes, the MultiSensor will reset the 
timing and start timing again.
The 4 minutes delay time can be changed through the usage of Z-Wave command 
built into Z-Wave certied control points. (The specic Z-Wave command supporting 
this function is Conguration Command Class) Please consult the operation manual 
for these control points for specic instructions on setting the MultiSensor.
Setting Motion Sensor delay time.
Parameter 3 [2 byte decimal] can be congured through your gateway in case the 
default settings of your MultiSensor are not what you desire.
For example, this parameter setting is initially set to 240 which is the delay time in 4 
minutes or 240 seconds.
You may set the value to the desired Motion Sensor delay time to any amount of 
seconds as you like. So if you want the time out to be 5 minutes after the Motion 
Sensor is triggered, set this parameter to 300.
Parameter 111 will set the interval for Group 1 (parameter 101), parameter 112 will 
set the interval for Group 2 (parameter 102), and parameter 113 will set the interval 
for Group 3 (parameter 103).
As an example, you have set parameter 101 to 225 which will report all of the 
sensors, and you want to report it every 1800 seconds. Set parameter 111 to 1800 to 
accomplish this.
If your MultiSensor is battery powered, you will need to ensure that it is active when 
conguring it. To do this, press and hold its Z-Wave Button for 3 seconds and then 
release it. Your MultiSensor’s LED should now be solid to indicate that it is active.
When you are done conguring or communicating with your MultiSensor, you can 
put it back into sleep mode to conserve battery power. To do this, press and hold its 
Z-Wave button for 3 seconds and then release it. Your MultiSensor’s LED should 
now be off to indicate that it is asleep.
At some stage or your primary controller is missing or inoperable, you may also wish 
to reset all of your MultiSensor’s settings to their factory defaults. To do this, press 
and hold the Z-Wave Button for 20 seconds and then release it. Your MultiSensor 
will now be reset to its original settings, and the LED will stay solid for 2 seconds and 
then turn off as a conrmation.
Power Supply: USB DC 5V or battery power(4×AAA batteries). 
Operating Temperature: -10 to 60 .
Measured Temperature Range: -10 to 50 . Accuracy: ±1 .
Humidity Range: 20% to 80%. Accuracy: ±5% (at 25   ).
Lighting: 0 to 1000 LUX.
Motion Sensitivity: 3 to 5 meters.
Water Proong: IP42.
Wireless Range: Up to 500 feet/150 metres outdoors.
Turn the Sensitivity Knob in a clockwise direction to increase sensitivity and counter-
clockwise to decrease sensitivity.
Your MultiSensor can report temperature, humidity, and luminance across a Z-Wave 
network when requested. If this function is supported by a controller, generally 
a gateway, the data  will be displayed  within its interface. The specic  Z-Wave 
commands for the support of monitoring is the Multilevel Sensor Command 
Class and Multi Channel Command Class. Automatic reports are sent to 
association group 1, which is setup via the Association Command Class. Please 
consult the controller’s operation manual for specic instructions on setting your 
MultiSensor.
Setting automatic report ags.
Parameter 101-103 [4 byte decimal] can be congured through your gateway in case 
the default settings of your MultiSensor are not what you desire.
The table above shows a decimal representation of all flags that can be set on 
parameter 101-103 to report specic data.
Example use of the report table.
For example, if you want to report only the temperature and light sensor you would 
add 32 + 64 and set the sum (96) to parameter 101, 102, or 103.
As another example, if you want to report only the light sensor and battery, you would 
add 1 + 128, then set the sum (129) to parameter 101, 102, or 103.
And if you want to report all of the sensors, you would add the whole table together 
and set the sum (225) to parameter 101, 102, or 103.
Setting an automatic report interval.
Parameter 111-113 [4 byte decimal] can be congured through your gateway in case 
the default settings of your MultiSensor are not what you desire.
Action  Button
Light Sensor
Humidity Sensor
Battery Sensor
Temperature Sensor
128
64
32
1
Technical specications. 
C
C
C
C
C
C
Warranty.
6
Aeon Labs warrants to the original purchaser of Products that for the Warranty Period 
(as dened below), the Products will be free from material defects in materials and 
workmanship. The foregoing warranty is subject to the proper installation, operation 
and maintenance of the Products in accordance with installation instructions and 
the operating manual supplied to Customer. Warranty claims must be made by 
Customer in writing within thirty (30) days of the manifestation of a problem. Aeon 
Labs' sole obligation under the foregoing warranty is, at Aeon Labs' option, to repair, 
replace or correct any such defect that was present at the time of delivery, or to 
remove the Products and to refund the purchase price to Customer. 
The "Warranty Period" begins on the date the Products is delivered and continues for 
12 months. 
Any repairs under this warranty must be conducted by an authorized Aeon Labs 
service representative and under Aeon Labs' RMA policy. Any repairs conducted by 
unauthorized persons shall void this warranty.
Excluded from the warranty are problems due to accidents, acts of God, civil or 
military authority, civil disturbance, war, strikes, res, other catastrophes, misuse, 
misapplication, storage damage, negligence, electrical power problems, or 
modication to the Products or its components. 
Aeon Labs does not authorize any person or party to assume or create for it any 
other obligation or liability in connection with the Products except as set forth herein. 
Aeon Labs will pass on to Customer all manufacturers’ Material warranties to the 
extent that they are transferable, but will not independently warrant any Material.
Customer must prepay shipping and transportation charges for returned Products, 
and insure the shipment or accept the risk of loss or damage during such shipment 
and transportation. Aeon Labs will ship the repaired or replacement products to 
Customer freight prepaid.
omissions of Customer or its ofcers, employees, subcontractors or agents, and/or 
(ii) arising from or relating to any actual or alleged infringement or misappropriation 
of any patent, trademark, mask work, copyright, trade secret or any actual or alleged 
violation of any other intellectual property rights arising from or in connection with the 
products, except to the extent that such infringement exists as a result of Aeon Labs' 
manufacturing processes. 
Customer shall indemnify, defend, and hold Aeon Labs and Aeon Labs' afliates, 
shareholders, directors, officers, employees, contractors, agents and other 
representatives harmless from all demands, claims, actions, causes of action, 
proceedings, suits, assessments, losses, damages, liabilities, settlements, 
judgments, fines, penalties,  interest,  costs  and  expenses (including fees and 
disbursements of counsel) of every kind (i) based upon personal injury or death or 
injury to property to the extent any of the foregoing is proximately caused either by a 
defective product (including strict liability in tort) or by the negligent or willful acts or 
IN NO EVENT SHALL AEON LABS BE LIABLE FOR ANY INDIRECT, INCIDENTAL, PUNITIVE, 
SPECIAL OR CONSEQUENTIAL DAMAGES, OR DAMAGES FOR LOSS OF PROFITS, REVENUE, 
OR USE INCURRED BY CUSTOMER OR ANY THIRD PARTY, WHETHER IN AN ACTION IN 
CONTRACT, OR TORT, OR OTHERWISE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH 
DAMAGES. AEON LABS' LIABILITY AND CUSTOMER'S EXCLUSIVE REMEDY FOR ANY CAUSE 
OF ACTION ARISING IN CONNECTION WITH THIS AGREEMENT OR THE SALE OR USE OF 
THE PRODUCTS, WHETHER BASED ON NEGLIGENCE, STRICT LIABILITY, BREACH OF 
WARRANTY, BREACH OF AGREEMENT, OR EQUITABLE PRINCIPLES, IS EXPRESSLY LIMITED 
TO, AT AEON LABS' OPTION, REPLACEMENT OF, OR REPAYMENT OF THE PURCHASE PRICE 
FOR THAT PORTION OF PRODUCTS WITH RESPECT TO WHICH DAMAGES ARE CLAIMED.  
ALL CLAIMS OF ANY KIND ARISING IN CONNECTION WITH THIS AGREEMENT OR THE SALE 
OR USE OF PRODUCTS SHALL BE DEEMED WAIVED UNLESS MADE IN WRITING WITHIN 
THIRTY (30) DAYS FROM AEON LABS'S DELIVERY, OR THE DATE FIXED FOR DELIVERY IN 
THE EVENT OF NONDELIVERY. 
THE INDEMNITY AND WARRANTY IN ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER 
INDEMNITIES OR WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING THE IMPLIED 
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
FCC NOTICE (for USA)
This device complies with Part 15 of the FCC Rules. Operation is subject to the 
following two conditions:
THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE 
CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT.SUCH MODIFICATIONS 
COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT.
STORE INDOORS WHEN NOT IN USE. SUITABLE FOR DRY LOCATIONS. DO NOT IMMERSE IN 
WATER. NOT FOR USE WHERE DIRECTLY EXPOSED TO WATER.
This device may not cause harmful interference, and 
This device m
ust accept any interference received, including interference that 
may cause undesired operation. 
1
2
Do not dispose of electrical appliances as unsorted municipal waste, use 
separate collection facilities.
Contact your local government for information 
regarding the collection systems 
available.
Warning
Certications (regional):
Z-Wave and Z-Wave Plus are registered trademarks of Sigma Designs and 
its subsidiaries in the United States and other countries
Decimal
Flag