User's Manual

Advanced functions.
Changing batteries.
Removing your MultiSensor from a Z-Wave network.
Monitoring motion.
Waking up your Multisensor.
Resetting your MultiSensor.
Adjusting the sensitivity of your MultiSensor .
Monitoring temperature, humidity and luminance.
If you’re using a Z-Stick:
If you’re using a Minimote:
Your MultiSensor has built in battery level detection. It will automatically report its
battery level to the associated control point throughout its life until the battery is fully
drained and needs replacing. The battery status will often be displayed in the user
interface of the control point.
When used properly in an optimised Z-Wave network, your MultiSensor can be
powered by batteries for 12 months before battery replacement is necessary.
Recommendation: For networks which do not offer a method to display the battery
level of your MultiSensor, it is recommended that the sensor be tested occasionally
to ensure that the batteries still hold enough charge to operate. Batteries naturally
lose their charge over time.
1. If your Z-Stick is plugged into a gateway or a computer, unplug it.
2. Take your Z-Stick to your MultiSensor.
3. Press and hold the Action Button on your Z-Stick for 3 seconds and then release.
4. Press the Z-Wave Button on your MultiSensor.
5. If your MultiSensor has been successfully removed from your network, its LED will
blink when you press the Z-wave Button. If the removal was unsuccessful, the LED
will stay solid for a few seconds when you press the Z-wave Button.
6. Press the Action Button on the Z-Stick to take it out of removal mode.
1. Take your Minimote to your MultiSensor.
2. Press the Remove Button on your Minimote.
3. Press the Z-wave Button on your MultiSensor.
4. If your MultiSensor has been successfully removed from your network, its LED will
blink when you press the Z-wave Button. If the removal was unsuccessful, the LED
will stay solid for a few seconds when you press the Z-wave Button.
5. Press any button on your Minimote to take it out of removal mode.
Your MultiSensor can be removed from your Z-Wave network at any time. You’ll
need to use your Z-Wave network’s main controller to do this and the following
instructions tell you how to do this using Aeotec by Aeon Labs’ Z-Stick and Minimote
controllers. If you are using other products as your main Z-Wave controller, please
refer to the part of their respective manuals that tells you how remove devices from
your network.
The MultiSensor can send Basic Set Command to association group 1, which
is setup via the Association Command Class, when the Motion Sensor detects
movement to control the associated devices to “OPEN” state. After 4 minutes by
default, if the Motion Sensor is not triggered again, the MultiSensor will send Basic
Set Command to these devices to set them to their “CLOSE” state. However, if the
Motion Sensor is triggered again within 4 minutes, the MultiSensor will reset the
timing and start timing again.
The 4 minutes delay time can be changed through the usage of Z-Wave command
built into Z-Wave certied control points. (The specic Z-Wave command supporting
this function is Conguration Command Class) Please consult the operation manual
for these control points for specic instructions on setting the MultiSensor.
Setting Motion Sensor delay time.
Parameter 3 [2 byte decimal] can be congured through your gateway in case the
default settings of your MultiSensor are not what you desire.
For example, this parameter setting is initially set to 240 which is the delay time in 4
minutes or 240 seconds.
You may set the value to the desired Motion Sensor delay time to any amount of
seconds as you like. So if you want the time out to be 5 minutes after the Motion
Sensor is triggered, set this parameter to 300.
Parameter 111 will set the interval for Group 1 (parameter 101), parameter 112 will
set the interval for Group 2 (parameter 102), and parameter 113 will set the interval
for Group 3 (parameter 103).
As an example, you have set parameter 101 to 225 which will report all of the
sensors, and you want to report it every 1800 seconds. Set parameter 111 to 1800 to
accomplish this.
If your MultiSensor is battery powered, you will need to ensure that it is active when
conguring it. To do this, press and hold its Z-Wave Button for 3 seconds and then
release it. Your MultiSensor’s LED should now be solid to indicate that it is active.
When you are done conguring or communicating with your MultiSensor, you can
put it back into sleep mode to conserve battery power. To do this, press and hold its
Z-Wave button for 3 seconds and then release it. Your MultiSensor’s LED should
now be off to indicate that it is asleep.
At some stage or your primary controller is missing or inoperable, you may also wish
to reset all of your MultiSensor’s settings to their factory defaults. To do this, press
and hold the Z-Wave Button for 20 seconds and then release it. Your MultiSensor
will now be reset to its original settings, and the LED will stay solid for 2 seconds and
then turn off as a conrmation.
Power Supply: USB DC 5V or battery power(4×AAA batteries).
Operating Temperature: -10 to 60 .
Measured Temperature Range: -10 to 50 . Accuracy: ±1 .
Humidity Range: 20% to 80%. Accuracy: ±5% (at 25 ).
Lighting: 0 to 1000 LUX.
Motion Sensitivity: 3 to 5 meters.
Water Proong: IP42.
Wireless Range: Up to 500 feet/150 metres outdoors.
Turn the Sensitivity Knob in a clockwise direction to increase sensitivity and counter-
clockwise to decrease sensitivity.
Your MultiSensor can report temperature, humidity, and luminance across a Z-Wave
network when requested. If this function is supported by a controller, generally
a gateway, the data will be displayed within its interface. The specic Z-Wave
commands for the support of monitoring is the Multilevel Sensor Command
Class and Multi Channel Command Class. Automatic reports are sent to
association group 1, which is setup via the Association Command Class. Please
consult the controller’s operation manual for specic instructions on setting your
MultiSensor.
Setting automatic report ags.
Parameter 101-103 [4 byte decimal] can be congured through your gateway in case
the default settings of your MultiSensor are not what you desire.
The table above shows a decimal representation of all flags that can be set on
parameter 101-103 to report specic data.
Example use of the report table.
For example, if you want to report only the temperature and light sensor you would
add 32 + 64 and set the sum (96) to parameter 101, 102, or 103.
As another example, if you want to report only the light sensor and battery, you would
add 1 + 128, then set the sum (129) to parameter 101, 102, or 103.
And if you want to report all of the sensors, you would add the whole table together
and set the sum (225) to parameter 101, 102, or 103.
Setting an automatic report interval.
Parameter 111-113 [4 byte decimal] can be congured through your gateway in case
the default settings of your MultiSensor are not what you desire.
Action Button
Light Sensor
Humidity Sensor
Battery Sensor
Temperature Sensor
128
64
32
1
Technical specications.
C
C
C
C
C
C
Warranty.
6
Aeon Labs warrants to the original purchaser of Products that for the Warranty Period
(as dened below), the Products will be free from material defects in materials and
workmanship. The foregoing warranty is subject to the proper installation, operation
and maintenance of the Products in accordance with installation instructions and
the operating manual supplied to Customer. Warranty claims must be made by
Customer in writing within thirty (30) days of the manifestation of a problem. Aeon
Labs' sole obligation under the foregoing warranty is, at Aeon Labs' option, to repair,
replace or correct any such defect that was present at the time of delivery, or to
remove the Products and to refund the purchase price to Customer.
The "Warranty Period" begins on the date the Products is delivered and continues for
12 months.
Any repairs under this warranty must be conducted by an authorized Aeon Labs
service representative and under Aeon Labs' RMA policy. Any repairs conducted by
unauthorized persons shall void this warranty.
Excluded from the warranty are problems due to accidents, acts of God, civil or
military authority, civil disturbance, war, strikes, res, other catastrophes, misuse,
misapplication, storage damage, negligence, electrical power problems, or
modication to the Products or its components.
Aeon Labs does not authorize any person or party to assume or create for it any
other obligation or liability in connection with the Products except as set forth herein.
Aeon Labs will pass on to Customer all manufacturers’ Material warranties to the
extent that they are transferable, but will not independently warrant any Material.
Customer must prepay shipping and transportation charges for returned Products,
and insure the shipment or accept the risk of loss or damage during such shipment
and transportation. Aeon Labs will ship the repaired or replacement products to
Customer freight prepaid.
omissions of Customer or its ofcers, employees, subcontractors or agents, and/or
(ii) arising from or relating to any actual or alleged infringement or misappropriation
of any patent, trademark, mask work, copyright, trade secret or any actual or alleged
violation of any other intellectual property rights arising from or in connection with the
products, except to the extent that such infringement exists as a result of Aeon Labs'
manufacturing processes.
Customer shall indemnify, defend, and hold Aeon Labs and Aeon Labs' afliates,
shareholders, directors, officers, employees, contractors, agents and other
representatives harmless from all demands, claims, actions, causes of action,
proceedings, suits, assessments, losses, damages, liabilities, settlements,
judgments, fines, penalties, interest, costs and expenses (including fees and
disbursements of counsel) of every kind (i) based upon personal injury or death or
injury to property to the extent any of the foregoing is proximately caused either by a
defective product (including strict liability in tort) or by the negligent or willful acts or
IN NO EVENT SHALL AEON LABS BE LIABLE FOR ANY INDIRECT, INCIDENTAL, PUNITIVE,
SPECIAL OR CONSEQUENTIAL DAMAGES, OR DAMAGES FOR LOSS OF PROFITS, REVENUE,
OR USE INCURRED BY CUSTOMER OR ANY THIRD PARTY, WHETHER IN AN ACTION IN
CONTRACT, OR TORT, OR OTHERWISE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH
DAMAGES. AEON LABS' LIABILITY AND CUSTOMER'S EXCLUSIVE REMEDY FOR ANY CAUSE
OF ACTION ARISING IN CONNECTION WITH THIS AGREEMENT OR THE SALE OR USE OF
THE PRODUCTS, WHETHER BASED ON NEGLIGENCE, STRICT LIABILITY, BREACH OF
WARRANTY, BREACH OF AGREEMENT, OR EQUITABLE PRINCIPLES, IS EXPRESSLY LIMITED
TO, AT AEON LABS' OPTION, REPLACEMENT OF, OR REPAYMENT OF THE PURCHASE PRICE
FOR THAT PORTION OF PRODUCTS WITH RESPECT TO WHICH DAMAGES ARE CLAIMED.
ALL CLAIMS OF ANY KIND ARISING IN CONNECTION WITH THIS AGREEMENT OR THE SALE
OR USE OF PRODUCTS SHALL BE DEEMED WAIVED UNLESS MADE IN WRITING WITHIN
THIRTY (30) DAYS FROM AEON LABS'S DELIVERY, OR THE DATE FIXED FOR DELIVERY IN
THE EVENT OF NONDELIVERY.
THE INDEMNITY AND WARRANTY IN ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER
INDEMNITIES OR WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
FCC NOTICE (for USA)
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions:
THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE
CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT.SUCH MODIFICATIONS
COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT.
STORE INDOORS WHEN NOT IN USE. SUITABLE FOR DRY LOCATIONS. DO NOT IMMERSE IN
WATER. NOT FOR USE WHERE DIRECTLY EXPOSED TO WATER.
This device may not cause harmful interference, and
This device m
ust accept any interference received, including interference that
may cause undesired operation.
1
2
Do not dispose of electrical appliances as unsorted municipal waste, use
separate collection facilities.
Contact your local government for information
regarding the collection systems
available.
Warning
Certications (regional):
Z-Wave and Z-Wave Plus are registered trademarks of Sigma Designs and
its subsidiaries in the United States and other countries
Decimal
Flag