Technical data

4 (c) 2012 Z-Wave Europe GmbH, Goldbachstr. 13, 09337 Hohenstein-Ernstthal, Germany, www.zwaveeurope.com
Value Description
0 Enabled parameter 91/92 (Default)
1 Disabled parameter 91/92
Minimum Change to send Report (Watt) (Parameter Number 91, Parameter Size 2) The value represents
the minimum change in wattage for a Report to be sent .
Value Description
0 — 32000 The value represents the minimum change in wattage. (Default 25)
Minimum Change to send Report (%) (Parameter Number 92, Parameter Size 1) The value represents the
minimum change in wattage Percent for a report to be sent. (Valid values 0‐100)
Value Description
0 — 100 The value represents the minimum change in wattage Percent. (Default 5)
Set 101‐103 to default (Parameter Number 100, Parameter Size 1)
Value Description
0 set to default (Default)
1 nothing
Report type send in Reporting Group 1 (Parameter Number 101, Parameter Size 4) Defines the type of
report sent for the Reporting Group 1.
Value Description
2 Multisensor Report
4 Meter Report for Watt
8 Meter Report for kWh (Default)
Report Type send in Reporting Group 2 (Parameter Number 102, Parameter Size 4) Defines the type of
report sent for the Reporting Group 2.
Value Description
2 Mutlisensor-Report
4 Meter Report for Watt
8 Meter Report for kWh
Report Type send in Reporting Group 3 (Parameter Number 103, Parameter Size 4) Defines the type of
report sent for the Reporting Group 3.
Value Description
2 Mutlisensor-Report