User Manual
14 19
Note:
The gang box should be sized 3×2×2.75 inch/
75×50×70 mm or larger, minimum volume 14
in / 230cm .
Use exible copper conductors only.
If a Bypass installation is needed, the Bypass
should be in parallel with the bulb load, see
below:
1).
2).
3).
3 3
Warning: The main circuit breaker or fuse must
be shut off during the Bypass installation or bulb
change.
Bypass
You can also set the external switch mode through
Conguration Command Class.
Parameter 120 [1 byte dec] is the parameter that
will set one of the 3 different modes. If you set this
conguration to:
(0) Enter automatic identication mode
(1) Momentary push button mode
(2) 3-way switch mode
(3) 2-state switch mode
Touch panel control.
As you can see that the Nano Dimmer’s surface has
a pin port, this port is used to connect the Touch
The Nano Dimmer can be controlled via 2-state
(ip/op) external/manual switch, momentary push
button or the 3-way switch. To automatically detect
and set the mode to the appropriate type of manual
switch wired into Nano Dimmer, toggle the button
on the manual switch once and wait 2 seconds
for the Nano Dimmer to detect the type of manual
switch.
Restore Power.
Restore power at the main circuit breaker or fuse.
5.