User's Manual
5
Include
If your Z-Stick is plugged into a gateway or a computer, unplug it.
Take your Z-Stick to your MultiSensor.
Press the Action Button on your Z-Stick.
Press the Action Button on your MultiSensor.
You can test if your MultiSensor has been successfully included 
into your Z-Wave network by pressing its Action Button. If 
you press the button and your sensor’s LED is solid for a few 
seconds, then inclusion has been successful. If the LED blinks 
when the button is pressed, the inclusion has been unsuccessful 
and you should repeat the above steps.
Press the Action Button on the Z-Stick to return it to standard 
operating mode. Return it to your gateway or computer.
Take your Minimote to your MultiSensor.
Press the Include button on your Minimote.
Press the Action Button on your MultiSensor.
You can test if your MultiSensor has been successfully included 
into your Z-Wave network by pressing its Action Button. If 
you press the button and your sensor’s LED is solid for a few 
If you’re using a Minimote:
1. 
2.
3.
4.
5.
6.
1. 
2.
3.
4.
Waking up your MultiSensor.
Tamper protection of your MultiSensor.
If your MultiSensor is battery powered, you will need to ensure that 
it is active when conguring it. To do this, press and hold its Z-Wave 
Button for 3 seconds and then release it. Your MultiSensor’s LED 
should now be solid to indicate that it is active.
When you are done configuring or communicating with your 
MultiSensor, you can put it back into sleep mode to conserve 
battery power. To do this, press and hold its Z-Wave button for 3 
seconds and then release it. Your MultiSensor’s LED should now 
be off to indicate that it is asleep.
The MultiSensor contains a smart Vibration sensor in. When 
someone attempts to disassemble your MultiSensor, it can detect 
the vibration and send an alarm notication to the main controller 
and let you know.
Parameter 111-113 [4 byte decimal] can be congured through your 
gateway in case the default settings of your MultiSensor are not 
what you desire.
Parameter 111 will set the interval for Group 1 (parameter 101), 
parameter 112 will set the interval for Group 2 (parameter 102), and 
parameter 113 will set the interval for Group 3 (parameter 103).
As an example, you have set parameter 101 to 227 which will report 
all of the sensors, and you want to report it every 1800 seconds. 
Set parameter 111 to 1800 to accomplish this.
16