User's Manual
The MultiSensor can send Basic Set Command to association 
group 1, which is setup via the Association Command Class, when 
the Motion Sensor detects movement to control the associated 
devices to “OPEN” state. After 4 minutes by default, if the Motion 
Sensor is not triggered again, the MultiSensor will send Basic Set 
Command to these devices to set them to their “CLOSE” state. 
However, if the Motion Sensor is triggered again within 4 minutes, 
the MultiSensor will reset the timing and start timing again.
The 4 minutes delay time can be changed through the usage 
of Z-Wave commands built into Z-Wave certified controllers/
gateways. (The specic Z-Wave command supporting this function 
is Configuration Command Class) Please consult the operation 
manual for these controllers/gateways for specic instructions on 
conguringthe MultiSensor.
Parameter 3 [2 byte decimal] can be configured through your 
gateway in case the default settings of your MultiSensor are not 
what you desire.
Monitoring motion.
Press the Action Button on your MultiSensor.
If your MultiSensor has been successfully removed from your 
network, its LED will blink when you press the Action Button. If 
the removal was unsuccessful, the LED will stay solid for a few 
seconds when you press the Action Button.
Press any button on your Minimote to take it out of removal 
mode.
3.
4.
5.
138
For optimal performance, your MultiSensor should NOT be 
mounted directly on or near metal framing or other large metallic 
objects. Large metal objects may weaken the Z-Wave wireless 
signal.
If selecting an outdoor location, it’s important to position your 
MultiSensor in a sheltered location. It is best if your MultiSensor 
is not directly exposed to rain, and is important that the humidity 
venting on your MultiSensor never is.
With your MultiSensor now part of your Z-Wave network, it’s time to 
nish its physical installation.
There are 2 ways that your MultiSensor can be mounted on on a 
wall or ceiling. Using the Back-Mount Plate, you can mount it at 
against a wall or ceiling. Using the Back-Mount Arm you can mount 
it on a surface or in a corner and angle it as desired.
To physically install your MultiSensor; 
Physically install your MultiSensor.
Reattach the two parts of your MultiSensor to each other. To do 
this, align the lock/unlock half-dimple markers that are under the 
unlock symbol and then twist in a clockwise motion.
If USB is used to power your MultiSensor, ensure that power 
can be provided to your desired installation location. Please note 
that when installed in areas that where the temperature can drop 
below -10°C, it is advised that USB power is used and battery 
power is not.
1. 
2.