User Manual
FCC NOTICE (for USA):
The MultiSensor can report temperature, humidity, and luminance to 
a Z-Wave gateway or controller when requested. If this function is 
supported by the gateway/controller, the data will be displayed in the 
user interface of the gateway/controller. (The specific Z-Wave 
command supporting the monitoring is the Multilevel Sensor 
Command Class and Multi Channel Command Class. Automatic 
reports are sent to association group 1, which is setup via the 
Association Command Class.) Please consult the operation manual 
for these gateways/controllers for specific instructions on setting the 
MultiSensor.
Do not dispose of electrical appliances as unsorted municipal waste, 
use separate collection facilities.
Contact your local government for information regarding the collection 
systems available.
THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR 
TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS 
TO THIS EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE 
USER’S AUTHORITY TO OPERATE THE EQUIPMENT.
STORE INDOORS WHEN NOT IN USE. SUITABLE FOR DRY 
LOCATIONS. DO NOT IMMERSE IN WATER. NOT FOR USE WHERE 
DIRECTLY EXPOSED TO WATER. 
This device complies with Part 15 of the FCC Rules. Operation is subject 
to the following two conditions:
1. This device may not cause harmful interference, and
2.This device must accept any interference received, including 
interference that may cause undesired operation. This equipment has 
been tested and found to comply with the limits for a Class B digital 
device, pursuant to part 15 of the FCC Rules. These limits are designed 
to provide reasonable protection against harmful interference in a 
residential installation. This equipment generates, uses and can radiate 
radio frequency energy and, if not installed and used in accordance with 
the instructions, may cause harmful interference to radio 
communications. However, there is no guarantee that interference will 
not occur in a particular installation. If this equipment does cause 
harmful interference to radio or television reception, which can be 
determined by turning the equipment off and on, the user is encouraged 
to try to correct the interference by one or more of the following 
measures:
 •Reorient or relocate the receiving antenna.
 •Increase the separation between the equipment and receiver.
 •Connect the equipment into an outlet on a circuit different from that
 to which the receiver is connected.
 •Consult the dealer or an experienced radio/TV technician for help.
Z-Wave Network Instructions:
The Aeotec MultiSensor must be paired (included) into a 
Z-Wave network before it can send Basic Set Command, 
Temperature, Humidity, and Light level reports to 
association group 1, which 
is  setup  via  the Association 
Command class.
 The MultiSensor can only communicate 
to devices within its own Z-Wave network.
Note: The LED on the MultiSensor will blink if it is currently 
not paired into a Z-Wave network when pressing the 
Z-Wave Button.
Adding/Including/Pairing the MultiSensor into a 
Z-Wave Network
Include
Associate
Learn
Remove
1
Press the button labeled “Include” on 
the Aeotec Minimote to begin the 
Z-Wave inclusion process.
Troubleshooting:  If the MultiSensor was not successfully paired 
into any Z-Wave network, the MultiSensor’s LED will blink when 
pressing the Z-Wave Button. If the MultiSensor was successfully 
paired into a Z-Wave network, the LED will stay solid for a few 
seconds when pressing the Z-Wave Button. 
Removing/Resetting the MultiSensor from your 
Z-Wave Network
Monitoring Temperature, Humidity and Luminance
Include
Associate
Learn
Remove
1
Press the button labeled “Remove” on 
the Aeotec Minimote to begin the 
Z-Wave removal process.
Remove
Note: To remove the MultiSensor from other controllers, 
please consult the operation manual for these controllers 
on how to remove Z-Wave products from an existing 
network. 
Note: To include the MultiSensor with other controllers, please 
consult the operation manual for these controllers on how to 
include Z-Wave products into an existing network.
Troubleshooting:  If the MultiSensor was successfully removed 
from the Z-Wave network, pressing the Z-Wave Button will cause the 
LED to blink. If the MultiSensor was not successfully removed from 
the Z-Wave network the LED will stay solid for a few seconds.
Warning:
Do not dispose of electrical appliances as unsorted municipal waste, 
use separate collection facilities.
Contact your local government for information regarding the collection 
systems available.
Certifications (regional):
Include
Warranty
Aeon Labs warrants to the original purchaser of Products that for the 
Warranty Period (as defined below), the Products will be free from 
material defects in materials and workmanship. The foregoing warranty 
is subject to the proper installation, operation and maintenance of the 
Products in accordance with installation instructions and the operating 
manual supplied to Customer. Warranty claims must be made by 
Customer in writing within thirty (30) days of the manifestation of a 
problem. Aeon Labs’ sole obligation under the foregoing warranty is, at 
Aeon Labs’ option, to repair, replace or correct any such defect that was 
present at the time of delivery, or to remove the Products and to refund 
the purchase price to Customer. 
The "Warranty Period" begins on the date the Products is delivered and 
continues for 12 months. 
Any repairs under this warranty must be conducted by an authorized 
Aeon Labs service representative and under Aeon Labs’ RMA policy. 
Any repairs conducted by unauthorized persons shall void this warranty.
Excluded from the warranty are problems due to accidents, acts of God, 
civil or military authority, civil disturbance, war, strikes, fires, other 
catastrophes, misuse, misapplication, storage damage, negligence, 
electrical power problems, or modification to the Products or its 
components. 
Aeon Labs does not authorize any person or party to assume or create 
for it any other obligation or liability in connection with the Products 
except as set forth herein. 
Aeon Labs will pass on to Customer all manufacturers’ Material 
warranties to the extent that they are transferable, but will not 
independently warrant any Material.
Customer must prepay shipping and transportation charges for returned 
Products, and insure the shipment or accept the risk of loss or damage 
during such shipment and transportation. Aeon Labs will ship the 
repaired or replacement products to Customer freight prepaid.
Customer shall indemnify, defend, and hold Aeon Labs and Aeon Labs’ 
affiliates, shareholders, directors, officers, employees, contractors, 
agents and other representatives harmless from all demands, claims, 
actions, causes of action, proceedings, suits, assessments, losses, 
damages, liabilities, settlements, judgments, fines, penalties, interest, 
costs and expenses (including fees and disbursements of counsel) of 
every kind (i) based upon personal injury or death or injury to property to 
the extent any of the foregoing is proximately caused either by a 
defective product (including strict liability in tort) or by the negligent or 
willful acts or omissions of Customer or its officers, employees, 
subcontractors or agents, and/or (ii) arising from or relating to any actual 
or alleged infringement or misappropriation of any patent, trademark, 
mask work, copyright, trade secret or any actual or alleged violation of 
any other intellectual property rights arising from or in connection with 
the products, except to the extent that such infringement exists as a 
result of Aeon Labs’ manufacturing processes.
IN NO EVENT SHALL AEON LABS BE LIABLE FOR ANY INDIRECT, 
INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL 
DAMAGES, OR DAMAGES FOR LOSS OF PROFITS, REVENUE, OR 
USE INCURRED BY CUSTOMER OR ANY THIRD PARTY, WHETHER 
IN AN ACTION IN CONTRACT, OR TORT, OR OTHERWISE EVEN IF 
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. AEON LABS’ 
LIABILITY AND CUSTOMER’S EXCLUSIVE REMEDY FOR ANY 
CAUSE OF ACTION ARISING IN CONNECTION WITH THIS 
AGREEMENT OR THE SALE OR USE OF THE PRODUCTS, 
WHETHER BASED ON NEGLIGENCE, STRICT LIABILITY, BREACH 
OF WARRANTY, BREACH OF AGREEMENT, OR EQUITABLE 
PRINCIPLES, IS EXPRESSLY LIMITED TO, AT AEOTEC’S OPTION, 
REPLACEMENT OF, OR REPAYMENT OF THE PURCHASE PRICE 
FOR THAT PORTION OF PRODUCTS WITH RESPECT TO WHICH 
DAMAGES ARE CLAIMED. ALL CLAIMS OF ANY KIND ARISING IN 
CONNECTION WITH THIS AGREEMENT OR THE SALE OR USE OF 
PRODUCTS SHALL BE DEEMED WAIVED UNLESS MADE IN 
WRITING WITHIN THIRTY (30) DAYS FROM AEON LABS’ DELIVERY, 
OR THE DATE FIXED FOR DELIVERY IN THE EVENT OF 
NONDELIVERY.
THE INDEMNITY AND WARRANTY IN ABOVE ARE EXCLUSIVE AND 
IN LIEU OF ALL OTHER INDEMNITIES OR WARRANTIES, WHETHER 
EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES 
OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR 
PURPOSE.
The MultiSensor can send Basic Set Command to association group 1, 
which is setup via the Association Command Class, when the Motion 
Sensor detects movement to control the associated devices to “OPEN” 
state. After 4 minutes by default, if the Motion Sensor is not triggered 
again, the MultiSensor will send Basic Set Command to these devices to 
set them to their “CLOSE” state. However, if the Motion Sensor is 
triggered again in 4 minutes, the MultiSensor will reset the timing and 
start timing again.
The 4 minutes delay time can be changed through the usage of Z-Wave 
command built into Z-Wave certified controllers/gateways. (The specific 
Z-Wave command supporting this function is Configuration Command 
Class) Please consult the operation manual for these controllers / 
gateways for specific instructions on setting the MultiSensor.
Monitoring Motion
Z-Wave Button
Sensitivity
AAA
AAA
AAA
AAA
2
Press the Z-Wave Button under the Battery Cover to begin the 
Z-Wave pairing process. 