User Manual

18
Press . Choose a recording duration between 1 minute and
99 weeks. Bear in mind that the life between charges of the
instrument is not that long (see § 6.3).
The recording time must be at least as long as the storage
period.
START DATE:
09/15/15
START TIME:
10:00:00AM
STOP DATE:
09/15/15
STOP TIME:
02:00:00PM
RECORDING:
START
DURATION:
15 min
You can start recording immediately by pressing
3 times.
The symbol is displayed.
Proceed in the same way if you want to stop recording before
the end of the programmed recording time.
If recording fails to start, it means that there is not enough
available space in memory for the recording. You must clear
the memory (see §4.6) to be able to record your session.
RECORDING:
STOP
DURATION:
15 min
You can also program the start- and end-of-recording times.
Press twice and choose the starting and stopping times.
The duration is adjusted automatically.
Or program the duration and the ending time is adjusted.
Press . Change the text Start to Schedule and validate by
pressing
. Recording is pending and will begin at the sched-
uled time. The symbol is displayed.
To cancel a programmed recording session, press
three
times.
RECORDING:
CANCEL
DURATION:
4 hours
You cannot switch the instrument off while recording is in progress.
If you press the On/Off
key, the instrument displays the screen
opposite and does not switch off.
But it is possible to switch it off if a recording session is pro-
grammed. The instrument will switch itself back on for the duration
of the recording, then switch off automatically.
RECORDING
ACTIVE
It is not possible to modify the conguration while recording is in progress. To change it, you must stop recording.