7Infinity-6/8h ECU Pinout
Infinity Pin
Hardware Specification
Notes
C1-1
Lowside switch, 1.7A max, NO
internal flyback diode.
See Setup Wizard Pages "User GPOs" for
activation criteria and "LowSide Assignment
Tables" for output assignment
C1-2
Lowside switch, 6A max with internal
flyback diode. Inductive load should
NOT have full time power.
See Setup Wizard Page "LowSide Assignment
Tables" for output assignment and 2D table
"LS5_Duty [%]" for activation.
C1-3*
Lowside switch, 6A max with internal
flyback diode. Inductive load should
NOT have full time power.
Available on P/N 30-7106 only. See Setup
Wizard Page "LowSide Assignment Tables" for
output assignment and 2D table "LS6_Duty
[%]" for activation.
C1-3**
For use with high impedance (10-15
ohms) injectors only, 1.7A max.
Available on P/N 30-7108 only
C1-4*
Lowside switch, 6A max, NO internal
flyback diode.
Available on P/N 30-7106 only. See Setup
Wizard Page "LowSide Assignment Tables" for
output assignment and 2D table "LS7_Duty
[%]" for activation.
C1-4**
For use with high impedance (10-15
ohms) injectors only, 1.7A max.
Available on P/N 30-7108 only
C1-5
Bosch UEGO controller
Lowside switch for UEGO heater control.
Connect to pin 4 of Bosch UEGO sensor. NOTE
that pin 3 of the Sensor is heater (+) and must
be power by a fused/switched 12V supply.
C1-6
Trim Current signal. Connect to pin 2 of Bosch
UEGO sensor
C1-7
Pumping Current signal. Connect to pin 6 of
Bosch UEGO sensor
C1-8
Nernst Voltage signal. Connect to pin 1 of
Bosch UEGO sensor
C1-9
Virtual Ground signal. Connect to pin 5 of
Bosch UEGO sensor.
C1-10
Dedicated power management CPU
Full time battery power. MUST be powered
before the ignition switch input is triggered
(See C1-48).
C1-11
25 mA max source current
0-5V Falling edge fire. DO NOT connect
directly to coil primary. Must use an ignitor
OR CDI that accepts a FALLING edge fire signal.
C1-12
25 mA max source current
0-5V Falling edge fire. DO NOT connect
directly to coil primary. Must use an ignitor
OR CDI that accepts a FALLING edge fire signal.
C1-13
25 mA max source current
0-5V Falling edge fire. DO NOT connect
directly to coil primary. Must use an ignitor
OR CDI that accepts a FALLING edge fire signal.
C1-14
25 mA max source current
0-5V Falling edge fire. DO NOT connect
directly to coil primary. Must use an ignitor
OR CDI that accepts a FALLING edge fire signal.
C1-15
25 mA max source current
0-5V Falling edge fire. DO NOT connect
directly to coil primary. Must use an ignitor
OR CDI that accepts a FALLING edge fire signal.
C1-16
25 mA max source current
0-5V Falling edge fire. DO NOT connect
directly to coil primary. Must use an ignitor