Owner's manual

Page 11
Do you want to use the Switched 12 volt DC source from the F/IC?
If so, connect the Switched 12 Volt source wire as shown below. (Note: The
driver can handle 1 amp max.) See Figure 20.
LOW CURRENT
RELAY/SOLENOID
SW12
FIC
Figure 20: Switched 12V
DC
connection
Do you want to use the Auxiliary Gauge in the F/IC?
If so, connect analog UEGO AEM no. 30-5130 as shown below. See Figure 21.
ANALOG UEGO
ANALOG OUT -
ANALOG OUT +
BROWN
WHITE
AUX IN
SIG GND
FIC
Figure 21: Analog UEGO gauge connection
Or connect digital UEGO AEM number 30-4100 as shown below. See Figure 22.
FIC
ANALOG OUT
DIGITAL UEGO
WHITE
AUX IN
Figure 22: Digital UEGO gauge connection