User's Manual
OUTPUT OPERATION ANNOUNCER (Location 72)
(1) LOCATION
Key in Location
(2) FUNCTION MODES FOR OUTPUT ANNOUNCER
Output announcer gives notification beep on the operation status of the outputs. There are two
notification modes available for the selection.The notification is also OFF while the Pacifier Tone OFF
mode in the Location 71 is selected.
--- No Notification
The output operation notification is OFF but does note affect the normal pacifier tones.
--- 1 Second Long Notification -- (Default)
1 second notification beep is given when the output relay activates. It is prepared to notify the
person outside the door when the lock is released and the door can be opened. It is good for door
lock that gives no sound when it activates, such as a magnetic lock.
--- 2 Short Beeps Notification
2 short beeps notification is given when the output relay activates.
(3) VALIDATION
Press
key once. Two-beep confirms the entry
STATUS LED FLASHING ON-OFF DURING STANDBY (Location 73)
(1) LOCATION
Key in Location
(2) FUNCTION MODES FOR STANDBY FLASHING LIGHT
Some people find the flashing light of the status LED (the amber LED) is annoying during standby,
especially at the night time. The standby flashing can be ON-OFF with the setting here.
--- Standby Flashing ON -- (Default)
The Status LED gives Standby Flashing all the time. It also gives the light indications showing the
operation status of the system.
--- Standby Flashing OFF
The Standby Flashing is OFF but it does not affect the system status indications.
(3) VALIDATION
Press
key once. Two-beep confirms the entry
FUNCTION MODES VALIDATIONLOCATION
or
(2) (3)(1)
FUNCTION MODES VALIDATIONLOCATION
or
(2) (3)(1)
NOTE:
In multi-station operation, the output announcer only goes to the keypad that has been operated but
not all the keypads in the system.
(iii) Pause the real-time inhibition manually
The real-time inhibition can be stopped temporarily if require; such as the staff work overtime in
office. The inhibition can be paused manually with Super User Code before or during the
inhibition period. The pause is toggle and does not affect the real time period counting.
---- Inhibition paused [Inhibit LED(Red) Flashing]
---- Inhibition resumes [Inhibit LED(Red) ON]
NOTE:
The “INHIBIT” LED(Red) is flashing during the paused period; and it is ON after inhibition resumes.
(iv) Open door lock with Super User Code at anytime
The Super User code is valid all the time even in the inhibition period. This function does not
affect the real time period counting.
---- The door is open
Super User Code
Super User Code
Super User Code
Programming and Operation Examples:
(i) Set the starting and stopping time for the real-time inhibition period
a) Set Inhibition Period from 12:30 PM (today) – 1:30 PM (same day) for lunch time:
b) Set Inhibition Period from 6:30 PM (today) – 8:15 AM (next day) for office close:
NOTE:
1) The start and stop time figures are 24 hours basis. They are 4-digit figures from the smallest
00:00 to the largest 23:59.
2) Entry of the two figure values from Small (Start) to Large (Stop) for the period of inhibition; the
inhibition will start and stop in the same day. See example (a).
3) Entry of the two figure values from Large (Start) to Small (Stop) for the period of inhibition; the
inhibition will start at the time of the day; thus stop in the next day. See example (b).
4) The keypad does not accept the “Start” and “Stop” times with same value. The two time figures
must be different.
(ii) Clear the function of inhibition
Clear the time settings to stop the function of inhibition: