User's Manual
Example 2: Set a “Duress Code” with the number of “2 3 9 8 0” for Output 2
(a) (b) (c) (d)
(a) Duress Code for Output 2, (b) Duress Code ID, (c) The Duress Code, (e) Entry Confirmation
Example 3: Delete an Output 1 “Duress Code” from Duress Code ID
in the memory
(a) (b) (c)
(a) Duress Code for Output 1, (b) The Duress Code ID, (c) Delete Confirmation
Example 4: Clear The Whole Group of Duress Codes from Location
:
(a) (b) (c)
(a) Group Location , (b) The Group Deletion Command, (c) Confirmation, all Duress Codes
in Location are cleared.
OPERATION AND FUNCTION OF THE DURESS CODE
The Duress Code(s) has double actions when it is keyed in. It activates the Duress Output (for duress
alarm) and at the same time activates the specific Relay Output 1, 2 or 3 just like a normal User Code.
The Duress Code always activates the Relay Output in its group, but, does not de-activate (stop) the
Duress Output. ONLY a normal User Code or Card in anyone of the user groups, or a Super User
Code can reset (de-activate) the Duress Output.
For Example:
Key in The Duress Code 3 3 6 9 of the Group 1 (for Output 1) To Command The Duress Function :
----- Duress Output activates (switches to (-) ground) & Output 1 activates.
Key in The Duress Code 3 3 6 9 in Group 1 (for Output 1) Again :
----- Duress Output keeps activating and no change in its state (keeps to (-)
Key in A Normal User Code to Reset Duress (For Example: 1369 is An User Code for Output 1):
----- Duress Output resets (back to OFF state) but does not activate Output 1.
NOTE:
1) Momentary Contact -- The Egress Delay starts to count when the egress button is momentarily
2)
3) The Egress Delay does not affect the operation of the User Codes/Cards for Output 1. The User
(4) VALIDATION
Press key once . Two-beep confirms the entry
EXAMPLES:
Example 1: Set Egress Button in Momentary contact of 5 seconds with delay & warning beep
(a) (b) (c) (d)
(a) Egress function programming, (b) Momentary contact with warning, (c) Delay time of 5 seconds
to release door, (d) Entry confirmation
Example 2: Set Egress Button in Holding contact of 10 seconds with warning beep
(a) (b) (c) (d)
(a) Egress function programming, (b) Holding contact mode with warning, (c) Holding time of 10
seconds to release door, (d) Entry confirmation
Example 3: Set Egress Button in Momentary contact without delay (This is the default setting)
(a) (b) (c) (d)
(a) Egress function programming, (b) Momentary contact without delay, (c) Release door instantly,
(d) Entry confirmation
pressed. Output 1 activates automatically (door is released) when the delay time reaches.
Codes/Cards always give INSTANT action.
ground) & Output 1 activates again.
EXAMPLES:
Example 1: Set a “Duress Code” with the number of “3 3 6 9” for Output 1
(a) (b) (c) (d)
(a) Duress Code for Output 1, (b) Duress Code ID, (c) The Duress Code, (e) Entry Confirmation
Holding Contact -- The user MUST hold the egress button in contact for the whole period of the
Egress Delay time until Output 1 activates. If the egress button is released before the end of the
Egress Delay, the timer will stop to count and reset.
For safety, it is necessary to put a sticker next to the egress button telling how to open the
door if “Holding Contact” is enabled.
Example: A sticker for an egress button that is programmed with “Holding Contact” of 5 seconds.
Press & Hold The Button
5 Seconds Minimum
Until The Door Is Open