User's Manual

PROGRAMMING
NOTE:
a) The button is equivalent to the button in the keypad with bell button.
b) Wait 1 minute until the end of power up delay, or keyin to stop the power-up delay
instantly and set the keypad to normal operation.
1) Set System in Programming Mode with The Factory Set Master Code 0 0 0 0
---- 2 beeps, system is in Programming Mode
Note: If the Master Code is forgotten, use the DAP Code to set the system into programming mode.
See DAP CODE 2828 in page 15 for the details.
2) Change The Factory Set Master Code to Owner’s Private Master Code for Security Reason
----
3) Record an “EM Card” to Operate The Output 1 for Door Open
(a) (b) (c) (d) (e)
(a) 10 = Programming Location for Output 1
(b) 1 = Programming option for EM Card only
(c) 001 = One of the 1,000 User IDs for the User
Code
/Card from 000-999
(d) Read Card = Put the Card close to the card reader
(e) # = Confirm the card is read, 2 beeps
4) Set an “User Code” to Operate The Output 1 for Door Open
(a) (b) (c) (d) (e)
(a) 10 = Programming Location for Output 1
(b) 2 = Programming option for User
Code
only
(c) 002 = One of the 1,000 User IDs for the User
Code
/Card from 000-999
(d) 8321 = The User
Code
for door open. It is for example here only
(e) # = Confirm the User
Code
, 2 beeps
OPERATION MODES (Location 94)
The keypad is programmable for keypad mode to work stand-alone for door control directly or for
server mode to work with a split-decoder for high security access control.
LOCATION OPERATION MODES VALIDATION
(1) LOCATION
Key in Location
(2) OPERATION MODES
– Keypad Mode (Default)
Keypad Mode sets the keypad for stand-alone operation to provide its available functions. It is
compatible with the auxiliary readers/keypads for multi-station expansion.
– Server Mode
Server Mode sets the keypad to compatible with both the decoder for split-decoded operation and
the auxiliary readers/keypads for multi-station expansion. A split decoded keypad system uses the
keypad(s) for human interface outside and the internal decoder for door lock control to prevent
sabotage.
(3) VALIDATION
Press key once. Two-beep confirms the entry
or 

(3)(2)
(1)
CLOSE PROGRAMMING MODE ( * * )
Always close programming mode with * * to set system back to normal Operation after
programming.
The button is equivalent to the button in the keypad with bell button.
VALIDATION
------------------------------- System is back to normal operation mode

7) Example 7 – Report A Duress While Using EM Card :
The Duress Codes are Prime User Codes in the system. In the “EM Card + Secondary User Code”
or “EM Card + Common User Code” operation, they can be used to replace the “Secondary User
Code” or the “Common User Code” to operate the specific output and report a duress alarm event.
Programming is not required. The system has this function automatically while Duress Code exists.
Operation : (while the system is in the operation mode)
(a) (b) (c)
(a) Read the EM card. Two-beep confirms the reading and 30 seconds waiting time is given for
entry of the Duress Code, the Amber LED keeps flashing
(b) Key in one of the Duress Codes for the specific output (the Code programmed in “Location 41,
42, or 43” for Output 1, 2 and 3 respectively)
(c) Confirm it with the # key. The specific Output activates in a normal way and the Duress Output
also activates to report Duress Event to an alarm system.
NOTE: The Duress Event can not be reported if the operation mode is EM Card alone. It is required
Duress CodeRead Card
to key in the Duress Code directly instead of EM card to report Duress Event.
5) Example 5 -- Delete An User Code & / or EM Card (for O/P 1, 2 or 3) :
i) Delete An User Code or A Lost EM Card
(a) (b) (c) (d)
(a) Key in the User Group that the User ID belongs to. “10” for Group 1, “20” for Group 2, and “30”
for Group 3
(b) Key in “5” that is the Command Code for making a deletion
(c)
Key in the User ID that stored the User Code, the lost EM card or the EM Card+User Code
(d) Press the # key. Two-beep confirms a valid entry and the Code and/or Card in that User ID is
cleared
ii) Delete an EM Card
(a) (b) (c) (d)
(a) Key in the User Group that the EM Card belongs to. “1 0” for Group 1, “2 0” for Group 2, and “3
0” for Group 3
(b) Key in “5” that is the Command Code for making a deletion
(c) Read the EM card. One-beep confirms the reading. Read the Card only also makes a valid deletion
to the Card working with the Common User Code or the Secondary User Code
(d) Press the # key. Two-beep confirms a valid entry. The EM Card in that User ID is cleared. Key in
the User ID is not required.
6) Example 6 – Clear The Whole Group of Users :
Whole group of users including the Codes and Cards can be cleared with the following command.
(a) (b) (c)
(a) The User Group 1 – “10” is selected to be cleared. “20” for Group 2 & “30” for Group 3
(b) Key in the Group Deletion Command, 0 9 9 9
(c) Confirm the deletion with #. All the User Codes and Cards in Group 1 are cleared. It takes few
seconds to a minute to complete depending on the data stored.
User ID
Read Card