LOCATION PARAMETERS DEFAULT FUNCTIONS & VALUES
0 1 Master Code 0 0 0 0 Factory Set, Not a default value *
0 2 Super User Codes Nil ----- User Program Required
0 3 Common User Code 1 Nil ----- User Program Required
0 4 Common User Code 2 Nil ----- User Program Required
0 5 Common User Code 3 Nil ----- User Program Required
1 0 User Codes & Cards for O/P 1 Nil ----- User Program Required
2 0 User Codes & Cards for O/P 2 Nil ----- User Program Required
3 0 User Codes & Cards for O/P 3 Nil ----- User Program Required
4 0 Visitor Codes Nil ----- User Program Required
4 1 Duress Code for O/P 1 Nil ----- User Program Required
4 2 Duress Code for O/P 2 Nil ----- User Program Required
4 3 Duress Code for O/P 3 Nil ----- User Program Required
5 1 O/P Mode of The O/P 1 Time = 5 Sec, Momentary
5 2 O/P Mode of The O/P 2 Time = 5 Sec, Momentary
5 6 Start & Stop Time Nil ----- User Program Required
5 5 System Real-Time-Clock Nil ----- User Program Required
5 3 O/P Mode of The O/P 3 Time = 5 Sec, Momentary
9 3 Wiegand Output Format Code = 1, 26-Bit
9 4 Operation Modes Code = 0,Keypad Mode
6 0 Personal Safety & Lock-out Code = 1, 10 False Code/Card Lock-out 60 Sec
7 0 User Code Entry Mode Code = 2, Manual Entry Mode
7 1
7 2 O/P Operation Announcer
7 3 Status LED Standby Flashing ON-
OFF
Code = 1, Flashing Enabled
8 0 Door Forced Open Warning & Timing Code = 0, Warning Disabled
8 1 Door Propped-up Warning & Delay Code = 0, Warning Disabled
9 0 Egress Delay & Warning Code 1 = 0, Instant, No Delay
Code 2 = 1, Momentary Contact without Warning
9 1 Door Opening Alarm & Timer Code = 0, Alarm O/P Disabled
9 2
Wiegand Output Mode
Code = 1, Disabled
Code = 1, Pacifier Tone ON
Code = 1 Sec, Notification Beep ON
Pacifier Tones ON-OFF Selection
THE DEFAULT VALUES AFTER REFRESHING
NOTE:
The DAP Code 2 8 2 8 and the Refreshing Code 9 9 9 9 are fixed in the operating system program.
It can not be changed in any ways.
PROGRAMMING SUMMARY CHART
LOCATION
FUNCTION
ENTRY LIMITS & CODE
OPTIONS
CODE ENTRY
FACTORY
DEFAULT
0 1
Master Code 4-8 Digits
MASTER CODE
NIL
0 2
Super User Code 4-8 Digits
SUPER USER CODE
NIL
0 3
Common User Code for
O/P 1
4-8 Digits
COMMON USER CODE 1
NIL
0 4
Common User Code for
O/P 2
COMMON USER CODE 2
NIL
0 5
Common User Code for
O/P 3
COMMON USER CODE 3
NIL
10
User Codes / Cards for
O/P 1
CODE 1
-
MEDIA:
1---EM Card
2---Private User Code
3---EM Card+Sec User Code
4---EM Card+Com User Code
5---Deletion of User Code
CODE 2
-
USER ID:
000-999---Group 1(10)
001-100---Group 2(20)
001-100---Group 3(30)
CODE 3
-
USER CODES /
Cards: 4-8 Digits / Cards
CODE1
CODE2
CODE3
NIL
20
User Codes / Cards for
O/P 2
CODE1
CODE2
CODE3
NIL
30
User Codes / Cards for
O/P 3
CODE1
CODE2
CODE3
NIL
4 0
Visitor Codes
CODE 1
-
VISITOR ID:
01-50
CODE 2
-
VALID PERIOD:
00---One Time
01-99 Hours
CODE 3
-
VISITOR CODE:
4-8 Digits
CODE1
CODE2
CODE3
NIL
4 1
Duress Code for O/P 1
CODE ID
-
O/P 1: 01-50
CODE ID
-
O/P 2: 01-10
CODE ID
-
O/P 3: 01-10
DURESS CODE: 4-8 Digits
CODE ID
DURESS CODE
CODE ID
DURESS CODE
CODE ID
NIL
4 2
Duress Code for O/P 2
NIL
4 3
Duress Code for O/P 3
NIL
5 1
O/P Mode for O/P 1
OUTPUT MODE & TIME:
0--- Start / Stop
1---99999 Seconds,
START TIME:
00:00-23:59
STOP TIME:
00:00-23:59
5 6
Start & Stop Times
for Inhibition
STOP TIMESTART TIME
NIL
CURRENT REAL TIME:
00:00-23:59
5 5
Real-Time-Clock
CURRENT TIME
NIL
Momentary
O/P MODE & TIME
5 Seconds
5 2
O/P Mode for O/P 2
O/P MODE & TIME
5 Seconds
5 3
O/P Mode for O/P 3
O/P MODE & TIME
5 Seconds
DURESS CODE
6 0
Personal Safety &
Lock-Up
LOCK-UP CODE:
1---10 Trial, Lock-Up 60 Sec.
2---10 Trial, Activates Duress
5-10---5-10 Trial, Lock-Up 15
Minutes
00---No Lock-Up
LOCK-UP CODE
Code = 1,
10 Trials,
Lock-Up 60
Seconds
7 0
Code Entry Mode
ENTRY MODE:
1---Auto Mode
2---Manual Mode
ENTRY MODE
Mode =
2, Manual
Mode