User's Manual
19 - 20 : TAMPER N.C. (Tamper Switch Normally Closed Contact)
A normally closed dry contact while the keypad is secured on its box. It is open while keypad is
separated from the box. Connect this N.C. terminal to the 24 hour protection zone of an alarm
system if necessary.
NOTE: The tamper switch in the DK-2882A and DK-2882B is activated by the fixing screw of the
front plate; in the DK-2882C and DK-2882D it is activated by a magnet equipped on the back of the
plastic box.
ON-BOARD LED INDICATORS
RED / GREEN (Right) ---
AMBER (Centre) ---------
RED / GREEN (Left) -------
PACIFIER TONES & THE LED SIGNALS
The buzzer and the amber LED indicator give following tones and signals respectively for system
status:
APPLICATION EXPANSIONS
Apart from standard-alone operation, DK-2882 is expandable to be a Multi-station System or a High
Security Multi-station Split-decoded System with its Data I/O Bus for the connection of the optional
auxiliary keypad(s) and decoder. The wiring is very simple. Just connect all the related devices in
parallel with the Data I/O Bus. The DK-2882 is the server that manages the data among them.
A Multi-station System provides higher security in access control and user convenience to operate an
electric lock at different locations. Such as a dual keypad system for area needs controlling of going
in and going out with user codes or EM cards.
A Split-decoded keypad system increases the overall security with keypad(s) installing outside and
decoder installing inside. It prevents the door can be opened due to sabotage at the external
keypad(s). A Split-decoded system is also compatible with the auxiliary keypads for multi-station
operation. It is a perfect system for overall higher security and user convenience.
The application examples here show the connections of the auxiliary keypads and the decoder to the
server keypad. Please contact your local agent for these optional devices if increasing security and
user convenience to the system is required.
The auxiliary reader / keypads and the decoders are compatible with all the 2nd generation keypads
in the DK-2800 series.
The version"A" auxiliary reader keypads are available, which provide Wiegand and RS-232 data
outputs.
654321
LED
DATA
I/O
TAMPER
N.C.
( + ) ( – )
12-24V DC
10987654321
LED
DATA
I/O
TAMPER
N.C.
( + ) ( – )
12-24V DC
WIEGAND
D0 D1
BUZ
RS
232
Version"A" ONLY
Connection Terminal
AR-2809AR-2806AR-2802 and AR-2807
10987
WIEGAND
D0 D1
BUZ
RS
232
Version"A" ONLY
It lights up in Green for Output 1 activation; and Red for Output 2
activation.
It flashes in Standby. It shows the system status in synchronization
with the beep tones. The standby flashing can be OFF with
programming. See Location 73 for the details.
It lights up in Red while one of the outputs is inhibited. It is flashing
during inhibition paused.
It is the Wiegand LED for feedback indication. It lights up in Green.
STATUS TONES * AMBER LED
1) In Programming Mode ----- ON
2) Successful Key Entry 1 Beep 1 Flash
3) Successful Code / Card Entry 2 Beeps 2 Flashes
4) Unsuccessful Code / Card Entry 5 Beeps 5 Flashes
5) Power Up Delay Continuous Beeps Continuous Flashes
6) Output Relay Activation ** 1 Second Long Beep
7) In Standby *** ----- 1 Flash in 1 Second Interval
8) System Refreshing ----- Fast Flashes for 2.5 Minutes
Continuous 3 Fast Beeps
/5 secs
-----
Continuous 1 Beep/5 secs
11) Real -time-clock stopped after
power failure
10) Keypad link-up with Decoder Failed
)9
Card or Code Already Stored in
System
1 Long Beep
-----
-----
-----
NOTE:
*
* *
* * *
JUMPER FOR BACK-LIT SELECTION
1) Full Back-lit ---
2) Auto Back-lit ---
All Pacifier Tones can be ON or OFF through the programming option at Location 71
The Output Relay Activation beep can be selected through the programming option at
Location 72
The Standby flashing can be ON or OFF through the programming option at Location 73
The keypad gives dim backlit in standby. It
turns to full backlit when a key button is
pressed, then back to dim backlit 10
seconds after the last key button is
pressed.
The backlit is OFF in standby. It turns to
full backlit when a key button is pressed,
then back to OFF 10 seconds after the last
key button is pressed.
FULL AUTO
BACK-LIT JUMPER
OTHER FACILITIES
Aux. Reader-KeypadAux. Reader-KeypadAux. Reader-KeypadAux. Reader
AR-2809AR-2807AR-2806AR-2802
The Axiliary Readers & Keypad (Optional)