Specifications
PRODUCT SPECIFICATIONS PRODUCT INDUCTION HOBS CERAMIC HOBS SEALED
HOBS PLATE HOBS
68001KFn
67600KFn
96901KFEn
76301KFn
79301KFn
66300KFan
66201KFn
6410KFn
C6010Kmn
C6010Kbn
111Km
111Kw
111Kd
MODEL
HOB FEATURES
Number of cooking zones 4 4 5 4 4 4 4 4 4 4
Control position Front Front Front Front Split sides Front Front Front Side Side
Control type Touch Controls Touch Controls Touch Controls Touch Controls Touch Controls Touch Controls Touch Controls Touch Controls Rotary Rotary
Residual heat / hob on indicator ■■■ ■ ■■■ ■■■
Electronic timer ■■■ ■■■■
Child lock ■■■ ■ ■■■ ■
Function lock ■■■
Auto Safety Switch-off ■■■ ■■■■
No of booster zones 4 1
Stop+Go ■ ■ ■■■■
Automatic booster ■ ■ ■■■
Pot recognition sensors ■■
ZONE SPECIFICATION
Front left spec 1) I I HI Triple HI Triple HI Triple HI Triple HI Dual HI Dual HI F
Front left rating kWh 2.2+0.8 2.2+0.8 1.8 2.3/1.6/0.8 2.3/1.6/0.8 2.3/1.6/0.8 2.3/1.6/0.8 2.2/0.75 2.2/0.75 2.0
Front left diameter mm 210 210 180 210/175/120 210/175/120 210/175/120 210/175/120 210/120 210/120 180
Front right spec 1) I I HI HI HI HI HI HI HI F
Front right rating kWh 1.8+0.5 1.4 1.8 1.2 1.8 1.2 1.2 1.2 1.2 1.5
Front right diameter mm 180 145 180 145 180 145 145 145 145 145
Rear left spec 1) I HI HI HI HI HI HI HI HI F
Rear left rating kWh 1.8+0.5 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.5
Rear left diameter mm 180 145 145 145 145 145 145 145 145 145
Rear right spec 1) I Multi HI Multi HI Multi HI Multi HI Multi HI Dual HI HI HI F
Rear right rating kWh 1.2+0.3 2.4/1.5 2.2/1.4 2.4/1.5 2.2/1.4 2.4/1.5 1.7/0.7 1.8 1.8 2.0
Rear right diameter mm 145 170x265 170x265 170x265 170x265 170x265 180/120 180 180 180
Middle front spec 1) Triple HI
Middle front rating kWh 1.05/1.95/2.7
Middle front diameter mm 145/210/270
ELECTRICAL CONNECTION
Total rating (max.) kWh 7.3 7.2 7.9 7.1 7.5 7.1 6.4 6.4 6.4 7.0
Fuse rating A 30 30 30 30 30 30 30 30 30 30
SAFETY AND INTERFERENCE SUPPRESSION
Low Voltage Directive (LVD)
■■■ ■ ■■■ ■■■
Electromagnetic Compatability (EMC) ■■■ ■ ■■■ ■■■
LITERATURE SUPPLIED
Operation and installation instructions ■■■ ■■■■ ■■■
APPLIANCE DIMENSIONS
Height (above worktop) mm 4* 4* 4* 4* 4* 5* 4* 4* 4* 8
Width mm 590 590 1029 780 720 605 590 590 570 580
Depth mm 520 520 519 520 520 535 520 520 500 500
Appliance weight Kg 11.1 11.1 12.5 10.5 10.3 9.5 7.6 7.6 8.0 11.9
APERTURE DIMENSIONS
Height mm 51 51 43 43 43 55 43 43 43 30
Width mm 560 560 995 750 680 560 560 560 560 550
Depth mm 490 490 490 490 490 490 490 490 490 470
PACKAGING DIMENSIONS
Packaged height mm 115 115 115 125 130 130 115 110 110 120
Packaged width mm 690 680 1105 995 795 655 680 665 665 670
Packaged depth mm 575 575 575 645 595 615 575 570 570 600
Packaged weight Kg 12.0 12.0 14.0 11.4 9.5 10.0 8.4 8.5 9.0 12.5
1) HI=HILIGHT zone; I=Induction; F=Fast plate
* Hob height: is height above worktop only
PRODUCT SPECIFICATIONS PRODUCT GAS HOBS
HOBS
99852Gm
99852Ga
79852Gm
79852Ga
95752Gbm
69802Gm
69802Ga
34942Gm
35772Gm
34602Gm
34602Gw
34602Gb
21602Gm
21602Gw
21602Gd
21602Gb
MODEL
HOB FEATURES
Number of cooking zones 5 5 5 4 5 5 4 4
Ignition type Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated
Control position Front Front Front Side Side Front Side Side
Cast iron wok support ■■ ■ ■
Cast iron pan supports ■■■■■■■
Safety thermocouples ■■ ■ ■
Stability fingers per burner 4 4 4 4 6 6 6 7
Stability feet ■■■■■■■■
ZONE SPECIFICATION
Front left spec 1) SR SR SR R R S R R
Front left rating 2) kWh 1.9 1.9 1.9 2.9 3.0 1.0 3.0 3.0
Front left diameter mm 62 62 62 98 98 48 98 98
Front right spec 1) S S S S S SR S S
Front right rating 2) kWh 1.0 1.0 1.0 1.0 1.0 2.0 1.0 1.0
Front right diameter mm 48 48 48 48 48 62 48 48
Rear left spec 1) SR SR SR SR SR R SR SR
Rear left rating 2) kWh 1.9 1.9 1.9 1.9 2.0 3.0 2.0 2.0
Rear left diameter mm 62 62 62 62 62 98 62 62
Rear right spec 1) SR SR SR SR SR SR SR SR
Rear right rating 2) kWh 1.9 1.9 1.9 1.9 2.0 2.0 2.0 2.0
Rear right diameter mm 62 62 62 62 62 62 62 62
Middle front spec 1) TC TC R TC TC
Middle front rating 2) kWh 3.9 3.9 2.9 4.0 4.0
Middle front diameter mm 120 120 92 120 110
Total rating (max.) 2) kWh 10.6 10.6 9.6 7.7 12.0 12.0 8.0 8.0
ELECTRICAL CONNECTION
Fuse rating A 3 3 3 3 3 3 3 3
SAFETY AND INTERFERENCE SUPPRESSION
Low Voltage Directive (LVD)
■■■■■■■■
Electromagnetic Compatability (EMC) ■■■■■■■■
Gas Directive ■■■■■■■■
LITERATURE SUPPLIED
Operation and installation instructions ■■■■■■■■
APPLIANCE DIMENSIONS
Height (above worktop)* mm 40 40 12 40 30 15 30 30
Width mm 880 680 740 580 860 680 580 580
Depth mm 510 510 520 510 500 510 500 500
Net weight Kg 16.6 15.6 15.6 11.1 15.1 11.1 8.2 8.2
APERTURE DIMENSIONS
Height mm 30 30 30 30 30 30 30 30
Width mm 830 560 560 550 830 560 550 550
Depth mm 480 480 480 470 470 480 470 470
PACKAGING DIMENSIONS
Packaged height mm 150 150 150 150 120 150 120 120
Packaged width mm 990 790 790 660 950 790 670 670
Packaged depth mm 620 620 620 600 600 620 600 600
Gross weight Kg 17.3 16.3 16.3 11.7 15.8 11.7 8.8 8.8
1) S=Simmer burner; R=Rapid burner; SR=Semi-Rapid; TC=Triple Crown
2) For gas conversion purpose 3.450 BTU = 1kW
*Hob height: is height above worktop only