AEG OXYGEN CENTRAL VACUUM SYSTEM Installation manual
AEG installation manual Contents Central Vacuum System Installation Location of the Power Unit ...........................3 Tubing System Design ..................................3 Location of Wall Inlet Valves...........................3 Typical Installation Examples .........................3 Installation of Wall Inlets ................................4 Tubing System Installation .............................7 VacPan Installation ........................................8 Exhaust Blow-Out .............
AEG installation manual Read these instructions carefully. Installation of the central vacuum system is easy and can be performed with regular hand tools. The system can be installed both in new and existing buildings. When using a central vacuum system, it is important to make sure there is a sufficient compensation air supply. Normal ventilation ensures that there is enough compensation air. This central vacuum system is very useful, and you can enjoy it for years to come.
AEG installation manual Installation of the Wall Inlet Valves min. 2 3/4” (65 mm) For the installation, you will usually need the following parts: mounting bracket inlet valve Mounting bracket Inlet valve 90° elbow Wall Installation of the Inlet Valve wall wall choose the best angle of the 90 ° inlet elbow so that it fits best in the surrounding space A typical wall inlet valve installation is shown in the figure on the right.
AEG installation manual 5 Thread the low voltage cable through the slot in the mounting bracket mm) 4 3/4” (110 mm) ” (60 2 3/8 low voltage cable min. 5/8 ” (15 cm ) ” 1/2 -2 m) ” 4 m / 2 1 7–62 (5 90° elbow Inlet Hole wall Make a hole in the board material for the inlet valve as shown in the figure. The size of the rectangular opening should be 2 3/8” x 4 3/4” (60mm x 110mm).
AEG installation manual Floor Installation of the Inlet Valve Installation in a Closet Wall This is usually the only possible installation method in existing houses. Choose a location and make a 2 1/8” x 2 3/4” (55mm x 70mm) opening for the inlet valve. For the tube, a 2 3/8” (60mm) diameter hole is needed. Drill a hole for the tube also in the floor of the closet. Cut the tube to the proper length and glue it into the rebuilding sleeve.
AEG installation manual 7 Tubing System Installation Begin the main tube installation with the farthest inlet valve and place the tubes temporarily at first. Do not glue the joints yet until you have made sure that the tubing routing is correct. The glue will dry quickly; therefore, the joints have to be fitted right after applying the glue. Important notes for installation! 1) The 90° inlet elbow may be installed only together with the mounting bracket and the inlet valve.
AEG installation manual Notes! Minimize Condensation If the tubing installation is carried out in winter, a large amount of condensation may be generated. To reduce the amount of condensation, close all pipe holes and inlet openings using duct tape during installation. Before starting to use the central vacuum system for the first time, let the system vacuum and circulate fresh air for a few minutes, and make sure that there is no water in the dust container.
AEG installation manual Exhaust Blow-Out Because the exhaust tube must be as short as possible, it is recommended to place the power unit as close to an outside wall as possible. Shown below are examples indicating how to install the exhaust tube. The exhaust muffler can be installed upwards, downwards, as well as horizontally. roo f exterior wall ceiling exterior wall ceiling insulation Min. 30cm (12”) ceiling exhaust valve exterior wall additional silencer Min. 30cm (12”) Min. 70cm (27.
AEG installation manual Electrical ConnectionLow-Voltage Cable To power on the central vacuum system, a 24V low-voltage cable is routed to each inlet valve. Parallel connection is made according to the figure below.