Specifications

7.2 Help by Telephone
Additional help in the determination and correction of faults is available by tele-
phoning AVITEQ Vibrationstechnik GmbH at (+49) 6145-503 0. We'll be glad
to help you if you have any questions!
Before you contact us, please go through the following checklist and note
the important information; it will help us provide you with faster and more
accurate telephone assistance.
General Information:
1 .1 Device t
yp
e
(
as stated on t
yp
e
p
late
)
1. 2 Device number
1 .3 Ma
g
netic vibrator t
yp
e: Nominal volta
g
e:
V
1 .4 Connector set t
yp
e: Nominal volta
g
e:
V
1 .5 Ambient tem
p
erature at vibrator: °C at Con. Dev.
°C
1 .6 Have the Vibrator or connector set been chan
g
ed?
Yes/No
1 .7 Since when has the device been in o
p
eration?
(
Month/Year
)
If the conveying capacity is too low:
2.1 Have modifications been made to the working unit, vibrator or connector set?
If yes. which (extended,
other wearin
g
p
lates. . .
)
Yes/No
2.2 Can the device vibrate freely? (is it due to stationary components or have conveying materials become
j
ammed?
)
Yes/No
2.3 Is caked-on matter
p
resent?
Yes/No
2.4 Knockin
g
or crackin
g
noises?
Y
es/No
2.5 Wearin
g
p
lates secure
(
where installed
)
?
Yes/No
2.6 Drive screws secure?
Yes/No
2.7 Conve
y
in
g
ca
p
acit
y
: Command value
(
t/h
)
: Actual value
(
t/h
)
: in
%
2.8 Workin
g
stroke: Intake:
a
pp
rox. mm
Outflow:
a
pp
rox. mm
2.9 Conve
y
in
g
material leadthrou
g
h-hei
g
ht at bunker outflow channel: a
pp
rox. mm
Conve
y
in
g
material leadthrou
g
h-len
g
th at bunker outflow channel: a
pp
rox. mm
2.1 0 Red LED "w> x" li
g
hts u
p
(
insufficient
p
ower
)
Yes/No
Red LED "HOT/ERROR x" li
g
hts u
p
Yes/No
If the Drive Unit does not vibrate:
3.1 Measure mains volta
g
e: Mains volta
g
e:
V
3.2 Fuse intact?
Yes/No
3.3 Vibrator voltage U
v
present at Vibrator? Measured value U
v
=
V
3.4 Vibrator current l
v
present? Measured value l
v
=
A
3.5 Command-value
p
otentiometer connected?
Y
es/No
3.6 Green LED "ON" li
g
hts u
p
(
mains volta
g
e ok
)
Yes/No
Green LED "START" li
g
hts u
p
(
=ON
)
Yes/No
Green LED "RUN" li
g
hts u
p
(
vibrator volta
g
e/i
g
nition
)
Yes/No
Yellow LED "w=0" li
g
hts u
p
(
command value = zero
)
Yes/No
Yellow LED 'PAL ON" li
g
hts u
p
(
if installed
,
PAL sensor in Vibrator o
p
eratin
g)
Yes/No
Red LED "HOT/ERROR x" li
g
hts u
p
(
bindin
g
p
osts 13/14 o
p
en
,
or PAL/tem
p
.-switch o
p
en
)
Yes/No
Red LED "w>x" lights up (insufficient power)
Yes/No