Specifications
8 Use an iron-vane meter or one which is True-KMS in the frequency range
from 0 to 500 Hz and compare the values with those specified by the manu-
facturer for the vibration conveyor device being used!
NOTE: When measuring current, only an RMS responsive measurement
instrument (iron vane or "True RMS" instrument for 0-500 Hz) must be
used. Other measurement instruments with a measuring range not
equal to 0-500 Hz (without DC) cannot measure non-sinusoidal values
correctly.
DANGER! Electrically live components. Risk of lethal electrical shock while con-
nected to mains. When carrying out the following measurements,
observe the specified protective measures!
In addition, measure the maximum working stroke and compare the value
with the data provided by the manufacturer for the vibration device being
used.
9 The permissible values for vibrator current and voltage specified in the type
plate must not be exceeded! Device-destroying collision mode may other-
wise result!
If the working stroke specified by the manufacturer cannot be reached,
check the natural frequency of the vibration device, if applicable.
NOTE