Specifications

4.4.2 Line Lengths
NOTE
NOTE: We define the line length as being the distance between vibration
conveyor device and main distributor. Smaller line cross sections or
longer line lengths could result in faults (see Chapter 7).
The maximum permissible line length is 300 m.
An appropriate line cross section is to be used for a given vibrator current.
The line cross sections (based on length) are given in the operating
manual for the magnetic vibrator.
NOTE: The maximum allowable voltage drop between the vibration
conveyor device and main distributor must not exceed a value of 5%.
The line cross sections in the operating manual for AVITEQ magnetic
vibrators are dimenstoned accordingly. When using a device
(magnetic vibrator) produced by another manufacturer, you must
mathematically recbeck the line resi
stance.
NOTE