Specifications

NOTE: To prevent switching faults, use only gold-plated or hermetically
sealed contacts.
NOTE: With external on/off switches, i.e. when binding posts 21,22 and
23, an assigned, the first switch on the DIP switch block is to be set to
OFF (left) (For details on the DIP switch block settings, see Chapter
5.3).
NOTE: Shield the signal lines to guarantee electromagnetic compatibility
if the lines exceed five metres in length!
Electrical
Connection
4.3.1 Notes on electrical connection
DANGER! Avoid accidents, observe regulations! When earthing, resetting, or
cm rying out protective switching, WE regulations (Germany) and
directives specifed by the responsible energy supplier are applicable!
The connection must be carried out only by trained personnel
(certified electrician or elet trically trained person in accordance with
IEC364 and EN 60204-1).
Switch off the current supply.
Check that no voltages are present!
Protect against unintentional reconnection!
Mains Fuse Protection
For mains fuse Fll (see Figure 4.11), we recommend a fuse appropriate
for th nominal current of the connected magnetic vibrator.
ATTENTION! ImproperJuses could result in damage to the magnetic
vibrator! Note the dimensioning of the mains fuses at the
installation site.