Specifications
4.2.6 Operational message and actual-value display
Operational message relay
The Connector Set is fitted with an operational message relay with change-over
con-
tact:
•
Make contact (31 and 30): Vibrator in operation
•
Break contact (31 and 32): Vibrator standstill, w=0 or START=off or
foult (HOT/ERRORx or w>x), the particular condition can be read from
the corresponding LEDs.
NOTE: The maximum load capacity of the operational message relay is,
for direct current, 60 W, and, for alternating current, 50VA.The
maximial voltages are, respectively, 30 V DC and 250 VAC.
ATTENTION! Destruction of the operational message relay and possibly of
the connector set! When dimensioning, note the permissible values
given above for the load of the operational message relay.
Actual-value display
It is possible to connect a digital actual-value display for the working stroke.
This additional device can be ordered under order number 58210132 from
AVITEQ Vibra-tionstechnik, Frankfurt, Germany. The binding post
assignments for the connection are shown in Figure 4.9. The mechanical
installation of the actual-value display is described in Chapter 4.3.4.