Specifications

ATTENTION! Destruction of the vibration sensor/temperature switch by
connecting to the false bindingposts! Never connect the two black
wires to binding posts 3 and 4!
NOTE: For line lengths longer than 50 m between magnetic vibrator and
connector set: use a separate cable for the two black vibration
sensor/temperature switch signal lines.
NOTE: Electromagnetic compatibility: if the line lengths are longer than 100
m, the two black signal lines must be shielded.
4.2.3 Vibration sensor (PA)
An external vibration sensor can be connected to Connector Set, type
SA(E)...-2S1 (see Figure 4.5).
Figure 4.5
External vibration sensor (binding posts 13 and 14)
NOTE: The installation of vibration sensor, type PA..., is described in the
separate appendix to this Operating Manual.
NOTE: Electromagnetic compatibility: if line lengths exceed five
metres, the signal lines must be shielded.
ATTENTION!
NOTE
NOTE
NOTE
NOTE