Specifications

NOTE: For Magnetic Vibrators without a vibration sensor and/or temperature
switch, binding posts 13 and 14 must be connected by a wire bridge.
If the bridge is missing, the red LED (HOT/ERROR x) lights up and the
operational message relay opens. As a result, the vibrator voltage at
binding posts 3 and 4 goes to zero; the Magnetic Vibrator ceases to
function.
NOTE: Use only potentiometers (limit values between 1 and 10 kOhm)
with linear characteristics for the vibration-width adjuster Shield the
signal lines to guarantee electromagnetic compatibility if the lines
exceed five metres in length!
4.2.2 Vibration sensor (PAL) and temperature switch
AVITEQ Magnetic Vibrators, series
• MV_S... (with temperature switch) and
• MV_S...P (with temperature switch and vibration sensor)
are fitted at the factory with a flexible, 5-conductor connection cable.
Remove the wire bridge from binding posts 13 and 14.
Connect the two black wires of the connection cable for the
temperature switch and/or vibration sensor to binding posts 13 and 14
(see Figure 4.4).
Figure 4.4
Vibration sensor and temperature switch (binding posts 13 and 14)
NOTE