Specifications
3.3 Scope of Operation
The VIBTRONIC Connector Sets of type SA(E)...-2 are designed for the following
regulation types:
• Voltage regulation
• Working stroke regulation
• Voltage regulation with limit protection
• Effective working stroke regulation
The various regulation types are described below.
Voltage-, working stroke- and effective working stroke regulation
Connector Sets of the type SA(E)...-2 can be operated with voltage regulation or
working stroke regulation with limit monitoring. Temperature monitoring of the
magnetic vibrator is also possible.
NOTE
NOTE: In normal operation the Connector Sets junction (without vibration sen-
sor PAL on the AVITEQ magnetic vibrators) as voltage regulators. If however,
AVITEQ-magnetic vibrators with PAL are used (type designation: MV..-...P),
limit protection in the upper control range is automatically regulated by means
of the working stroke.
Connector Sets of type SA(E)...-2S1 are set in the factory for effective working
stroke regulation by means of an external vibration sensor (type: PA...).
Temperature monitoring is possible.
NOTE
NOTE: The Connector Sets function as a voltage regulator when binding posts
13 and 14 are bridged. In this case, a magnetic vibrator must not be operated
with a vibration sensor (PAL)!
Presetting the Command Value
The command value for the working stroke can optionally be preset by means of
•
a vibration-width adjuster (potentiometer) or
•
an external control input (0...10 V, 4...20 mA or 0...20 mA)