Technical data
Principles of Vibration Conveyor Technology – Tuning data for the KF and KR series
7–4
Due to the complex tuning process, this work should be undertaken at AViTEQ
Vibrationstechnik’s laboratory. If the intended working weight is specified in
advance, AViTEQ will be able to tune the drive unit to suit. In an ideal situation, the
working unit constructed by the user should accompany the unit for the factory
tuning.
When constructing your own working units, you should ensure that sideway fol-
ding of the (trough) edges or other stiffening measures are used to achieve suf-
ficient stiffness of the working unit if larger dimensions, thin metal sheets, or low
side walls are used.
Note the following facts when making changes to drive and working unit! Additio-
nal technical data may be found in the AViTEQ brochure „Small Conveyor Units“.
Drive type KF 0,3 KF 0,5-1 KF 0,7-1 KF 0,9-1 KF 1-2 KF 6-2 KF 12-2 KR-2 Remarks
working weight
(ideal)
0.3 kg 0.5 kg 1.5 kg 3.0 kg 1.5 kg 3.0 kg 6.0 kg 0.8 kg standard adjustment,
see type label for wor-
king weight
working weight
(max.)
0.5 kg 0.8 kg 2.7 kg 5.5 kg 3.5 kg 7.0 kg 15.0 kg 1.5 kg maximum value,
tuning by AViTEQ for
working weights other
than standard (tuning
best done in combina-
tion with working unit)
tightening torque
for spring moun-
ting bolts
5 Nm 7 Nm 12 Nm 12 Nm 12 Nm 30 Nm 50 Nm 12 Nm
air gap ~0.7 mm ~0.8 mm ~0.9 mm ~3.3 mm ~1.0 mm ~2.5 mm ~3.5 mm ~1.8 mm
eigenfrequency
for 50 Hz AC
mains
109...110 Hz 108...109 Hz 108...109 Hz 57...60 Hz 105...106 Hz 57...58 Hz 57...58 Hz 57...58 Hz
current consump-
tion (max.)
0.06 A 0.07 A 0.32 A 1.20 A 0.20 A 0.85 A 2.20 A 0.27 A
vibrator voltage 230 V 230 V 210 V 210 V 210 V 210 V 210 V 210 V measured with a true
RMS meter at
230 V/50 Hz
vibration width
set via associa-
ted controller
0.4...0.5 mm 0.4...0.5 mm 0.6...0.7 mm 1.4...1.6 mm 0.5...0.6 mm 1.4...1.5 mm 1.4...1.5 mm 0.7...0.8 mm type designation (cf.
leaflet „Small Con-
veyor Units“)
stopper voltage 242 V 242 V 242 V 242 V 242 V 242 V 242 V 242 V via controller
vibration fre-
quency at 50 Hz
mains frequency
6,000 min
-1
6,000 min
-1
6,000 min
-1
3,000 min
-1
6,000 min
-1
3,000 min
-1
3,000 min
-1
3,000 min
-1
Table 7.2 Tuning data for small conveyor units
NOTE