Technical data

Operating Manual for AViTEQ Small Conveyor Units KF and KR
©1999 AViTEQ Vibrationstechnik GmbH Version 10/1999
4–5
4
4.3 Controllers from third party manufacturers
Observe the following hints if you do not want to use an AViTEQ VIBTRONIC con-
troller:
Amongst other information, you can find the following specifications on the type
label of an AViTEQ small conveyor unit:
l
Type
l
Vibration frequency in vibrations per minute
l
Drive voltage
l
Mains frequency
l
Drive current
When selecting a suitable controller, the drive voltage, mains frequency, drive cur-
rent, and vibration frequency stated on the type label must be observed under any
circumstances!
F
The specified values for current, voltage, and frequency must not be excee-
ded as the small conveyor unit may be destroyed by stopper-to-stopper ope-
ration.
F
When checking the currents and voltages, use an RMS meter only. Do not
use an off-the-shelf multimeter as it cannot display non-sinusoidal values cor-
rectly.
F
The third-party controller must generate a sinusoidal drive voltage. Operation
of the small conveyor drive with square wave voltages is not permissible and
may lead to the destruction of the drive!
Operation with an unsuitable controller or without controller, or connection to
incorrect mains voltage/frequency results in drive damage. Make sure that the
connection values are correct and compare them with the type labels! AViTEQ
does not accept responsibility if controllers of third-party manufacturers are used!
ATTENTION!