Technical data

Operating Manual for AViTEQ Small Conveyor Units KF and KR
©1999 AViTEQ Vibrationstechnik GmbH Version 10/1999
4–3
4
4.2.3 Combinations of small conveyor drive / controller
Always use Table 4.2 (controllers without voltage regulation) and Table 4.3 (con-
trollers with voltage regulation) to check prior to installation whether your control-
ler is suitable for the existing small conveyor unit! Also check the mains speficiati-
ons as stated on the type label!
Type Nominal
current
(A)
Protection
type EN
60529
Weight
(kg)
Vibration
frequency
(min
-1
)
Matching
conveyor
units
Remarks
SU-B50-1 3.0 IP 65 0.6 3,000 KF 0,9/6/12,
KR-2
4 ... 20 mA DC
SUE-B50-1 3.0 IP 00 0.2 3,000 KF 0,9/6/12,
KR-2
4 ... 20 mA DC
SW-A100-1 0.1 IP 55 0.6 6,000 KF 0,3/0,5 without soft start
SU-A100-1 0.1 IP 65 0.6 6,000 KF 0,3/0,5 4 ... 20 mA DC
SUE-A100-1 0.1 IP 00 0.2 6,000 KF 0,3/0,5 4 ... 20 mA DC
SU-B100-1 3.0 IP 65 0.6 6,000 KF 0,7/1 4 ... 20 mA DC
SUE-B100-1 3.0 IP 00 0.2 6,000 KF 0,7/1 4 ... 20 mA DC
Table 4.2 VIBTRONIC controllers without voltage regulation, with soft start, for 230 V
mains at 50 Hz
Type Nominal
current
(A)
Protection
type EN
60529
Weight
(kg)
Vibration
frequency
(min
-1
)
Matching
conveyor
units
Remarks
SC-C50-1 5 IP 55 6 3,000 KF 0,9/6/12 4 ... 20 mA DC
0...10 VDC
0 ... 20 mA DC
SC-C50-1 5 IP 20 2 3,000 KF 0,9/6/12,
KR-2
4 ... 20 mA DC
0...10 VDC
0... 20 mA DC
Table 4.3 VIBTRONIC controllers with voltage regulation, with soft start, for 230 V
mains at 50 Hz