Technical data
Installation of the Small Conveyor Drive – Mounting the small conveyor unit on the base plate
3–10
Insufficient attachment of the conveyor unit! Ensure that the attachment bolts have
the correct length! The bolts must not reach the bottom of the mould in the feet, as
this prevents safe attachment of the conveyor unit and results in the destruction of
the rubber feet!
3.2.3 Sound pressure level
The small conveyor drive generates a sound pressure level of less than 70 dB(A)
without considering the working unit or the transported material. Depending on
the construction of the working unit and the acoustic properties of the material
transported, the sound pressure level of the operational small conveyor unit may
exceed 70 dB(A). It is the operator’s responsibility to ensure adherence to the
sound pressure level permitted by means of suitable noise protection measures!
Drive Bolt size
Spring mount
Tightening torque
for bolts
(quality 8.8)
Minimum and maxi-
mum bolt length inside
rubber foot
KR-2 M 6 8 Nm (M6) 3...5 mm
KF 0,3 M 4 2.4 Nm (M4) 3...4 mm
KF 0,5 M 5 5 Nm (M5) 3...5 mm
KF 0,7 M 6 8 Nm (M6) 3...5 mm
KF 0,9 M 6 8 Nm (M6) 5...8 mm
KF 1 M 6 8 Nm (M6) 3...5 mm
KF 6 M 8 20 Nm (M8) 5...8 mm
KF 12 M10 40 Nm (M10) 5...8 mm
Table 3.9 Recommended tightening torques for the mounting bolts and permissible
bolt length inside the rubber feet
ATTENTION!