Operation Manual
EN
1
3
13
Activated Charcoal Filter (Recirculation Version) 
This cannot be washed or regenerated, and must be changed at least once every 4 months, or 
when led H starts to flash. The alarm signal only appears when the Suction motor is turned on. 
Activating the alarm signal 
•  In Recirculation Version Hoods, the Filter Saturation Alarm must be activated on installa-
tion or at a later date. 
•  Turn the Lights and the Suction Motor off. 
• Press button G. 
•  Within 5 seconds, press Button H until Led H flashes in confirmation: 
  •  Led flashes twice – Activated Charcoal Filter saturation alarm ACTIVATED. 
  •  Led flashes once – Activated Charcoal Filter saturation alarm DEACTIVATED. 
Changing the Activated Charcoal Filter 
Resetting the alarm signal 
•  Turn the Lights and the Suction Motor off. 
• Press button H. 
Changing the Filter 
•  Open the comfort panels pulling them downwards. 
•  Remove the metal grease filters. 
• Remove the saturated charcoal filter by releasing the fixing 
hooks 
•  Fit the new filter and fasten it in its correct position. 
•  Put the metal grease filters in their seats. 
•  Close the comfort panels. 
Lighting 
LIGHT REPLACEMENT 
20 W halogen light. 
•  Remove the 2 screws fixing the Lighting support, and pull it 
out of from the Hood. 
•  Extract the lamp from the Support. 
•  Replace with another of the same type, making sure that the 
two pins are properly inserted in the lamp holder socket holes. 
•  Refit the Support, fixing it in place with the two screws re-
moved as above.  