Activated Charcoal Filter (Recirculation Version)
This cannot be washed or regenerated, and must be changed at least once every 4 months, or
when led H starts to flash. The alarm signal only appears when the Suction motor is turned on.
Activating the alarm signal
In Recirculation Version Hoods, the Filter Saturation Alarm must be activated on installa-
tion or at a later date.
Turn the Lights and the Suction Motor off.
• Press button G.
Within 5 seconds, press Button H until Led H flashes in confirmation:
Led flashes twice – Activated Charcoal Filter saturation alarm ACTIVATED.
Led flashes once – Activated Charcoal Filter saturation alarm DEACTIVATED.
Changing the Activated Charcoal Filter
Resetting the alarm signal
Turn the Lights and the Suction Motor off.
• Press button H.
Changing the Filter
Open the comfort panels pulling them downwards.
Remove the metal grease filters.
Remove the saturated charcoal filter by releasing the fixing
hooks
Fit the new filter and fasten it in its correct position.
Put the metal grease filters in their seats.
Close the comfort panels.
Lighting
LIGHT REPLACEMENT
20 W halogen light.
Remove the 2 screws fixing the Lighting support, and pull it
out of from the Hood.
Extract the lamp from the Support.
Replace with another of the same type, making sure that the
two pins are properly inserted in the lamp holder socket holes.
Refit the Support, fixing it in place with the two screws re-
moved as above.