User guide

Problem Possible cause Solution
Power does not reach the appli-
ance
Try connecting another electrical
device to the power outlet
The appliance is not switched on Switch on the appliance
There is no voltage in the mains
socket (try to connect another
appliance into it)
Call an electrician
The appliance does not
cool at all
Plug is not connected to the
mains socket properly
Connect the mains plug properly
There is no voltage in the mains
socket (try to connect another
appliance into it)
Call an electrician
The appliance is not switched on Switch on the appliance
Temperature Regulator is not on Check the Temperature Regulator
Green indicator flashing
Temperature sensor problem Call the service personnel
Closing the door
1. Clean the door gaskets.
2. If necessary, adjust the door. Refer to "Installation".
3. If necessary, replace the defective door gaskets. Contact the Service Center.
TECHNICAL DATA
Dimension
Height 850 mm
Width 595 mm
Depth 635 mm
Rising Time 24 h
The technical information are situated in the rating plate on the internal left side of the
appliance and in the energy label.
INSTALLATION
WARNING!
Read the "Safety Information" carefully for your safety and correct operation of the ap-
pliance before installing the appliance.
Technical data
27