USER MANUAL Protect alpha. Protect alpha.
CONTENTS 1. Safety – caution.................................................................................. 3 2. Introduction........................................................................................ 5 3. Trouble shooting................................................................................. 6 4. System description............................................................................. 7 4.1. Inspection......................................................................
1. SAFETY – CAUTION • This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user serviceable parts. Only qualified service personnel may perform repairs. • Internal battery voltage is 24 V DC. Sealed, lead-acid, 6 cell battery – two pcs. • Connection to any other type of socket other than a two-pole, three-wire grounded socket may result in shock hazard as well as violating local electrical codes.
• Servicing of batteries should be performed or supervised by personnel trained in batteries and the required precautions. Keep unauthorized personnel away from batteries. • When replacing batteries, replace with the same number and type of sealed lead-acid batteries. The maximum ambient temperature rating is 40 °C. • This pluggable type A equipment, with battery already installed by the supplier, is operator installable and may be operated by non-technical users.
2. INTRODUCTION This UPS is specially designed for Personal Computer use and has multiple functions. Its light weight, compact design fits perfectly to the limited working environment. This line of UPS is equipped with boost and buck AVR to stabilize input voltage range. It is also built-in with a DC-start function. This function enables the UPS to be started without an AC power supply.
3. TROUBLE SHOOTING Symptom Possible Cause Remedy No LED display on the front panel 1. Battery weak 1. Charge battery for up to 8 hours 2. Battery defective 2. Replace with the same type of battery 3. Power switch is not pressed 3. Press the power switch again Alarm buzzer Overload of the UPS beeps continuously when AC supply is normal Verify that the load matches the UPS capability specified in the specs In event of power failure, back-up time is shortened 1.
4. SYSTEM DESCRIPTION Front panel 1. Power switch LED indicators: 2. Normal: Green 3. Battery mode: Yellow flashing 4. AC mode: Green 5. Fault mode: Red Back panel 1. AC input 2. Output sockets 3. USB & RJ45 communication 4.1. INSPECTION Remove the UPS from its packaging and inspect it for damage that may have occurred during shipping. If any damage is discovered, repack the unit and return it to the place of purchase.
4.2. CHARGING This unit is shipped from the factory with its internal battery fully charged, however, some charge may be lost during shipping and the battery should be recharged prior to use. Turn on the UPS, plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 6 hours with no load connected (i.e. no electrical devices such as computers, monitors, etc.). 4.3.
4.4. CONNECTION Plug the UPS into a 2-pole, 3-wire grounded socket. Then connect one computer-related device into each of the power sockets supplied on the back of the UPS. 4.5. TURN ON/OFF To turn on the UPS unit, press the power switch lightly. To turn off the UPS unit, press the power switch again. 4.6. DC-START All Protect alpha. UPSs are equipped with DC-start. To start the UPS when AC utility power is not available, simply press the power switch. 4.7. GREEN POWER FUNCTION All Protect alpha.
5. SPECIFICATION MODEL Protect alpha.
6.
SERIAL NUMBER: PURCHASE DATE: DEALER STAMP/SIGNATURE Emil-Siepmann-Str. 32 59581 Warstein-Belecke – Germany Tel.: +49 180 523 4787 – Fax: +49 180 523 4789 www.aegps.com AEGPS - Protect alpha. 1200 - EN - 05/2013 V1 - Technical data in this document does not contain any binding guarantees or warranties. Content only serves for information purposes and can be modified at any time.