7.1 Indicators
The device has 9 indicators.
OP ANT
READ
NoREAD
ERR Tx
RX
BusFail
Run
Figure 7-1: Position of all LED Indicators
Their function is:
OP: flashing as long as the microprocessor is working properly - life indication
ANT: on if antenna is operated
READ: on if last read was successful
NoRead: on if last read was not successful
ERR: on if a hardware error was detected, i.e. antenna is faulty or missing
Run: on, if slave is in the state data_exchange (Profibus Run)
BusFail: on, if slave is not in the state data_exchange (Profibus Fail)
RX: on as long as new information are received from the PLC (commands)
TX: on as long as new information is transmitted to the PLC (answers)
8 Integration into the Profibus Network
If the device is running due to chapter 7 all to do is to integrate the slave into the PLC environment.
The steps are that one which are common when integration a Profibus slave:
• load GSD-file into the PLC
• Check existing Profibus network for unused slave adress. Adjust unused slave adress in the ARE
K1/PFB device (see chapter 6)
• Check position of termination switch of the ARE K1 /PFB device, only the device at the end of
the network line has to be terminted!
• Allocate the node adress in the PLC