User Guide
--------------------------------------------------------------------------------10/18--------------------------------------------------------------------------------
• Fasten nut (5) of the cable pipes with the right tool (17mm).
• Do this carefully, to ensure the tightness of the protection class of IP 65.
5.3.5 Plug in of the SAB Cab
Attention !
Before plugging the SAB cab to the connectors of the reader, make sure that the grounding of the
device is well done. Otherwise the electronic may be destroyed by electrostatic discharge.
1
1
2
2
A
A
B
Figure 5-5: Plug-in of the SAB Cab
• Put on the sealing ( (2) in Figure 5-5 ) to the SAB cab (A).
• Plug in the SAB cab to the connector at the bottom of the reader box (B).
• There is only one way to plug in the SAB cab to the connector rim of the reader.
• Fasten the SAB cab with the help of the screws.
5.3.6 Connection to the Power Supply
Use a power supply of 24V
DC
. A current of aprox. 1,0 A is needed in full operation mode.
5.3.7 Connection characteristics of the digital inputs
The reader is equipped with an galvanic disconnected digital input. The positive edge
causes a trigger signal. The input voltage is 24 V.
5.3.8 Connection to the Antenna
The antenna is connected to the port ANT of the ARE K1 / PFB using the provided antenna cable. In-
side the cable signals of a very small amplitude are conducted, so attention should be paid, that no in-
terfering signals are coupled in. So don't use cabel tranch with other cables.
Best results will be produced using the original cables of AEG ID. This cables are ready to use and are
ideal fitted to the system regarding shielding and capacity of the cable.