User's Manual
--------------------------------------------------------------------------------9/13--------------------------------------------------------------------------------
3 Firmware
The reader supports ASB (AEG ID standard set of instructions). When delivered the reader´s configuration is
set into the operation mode 2 (readings triggered by serial interface).
The reader can be set to the operation mode 0 (continuous operation) or to the operation mode 1 (triggered by
external input).
The parameters NRD and NID should only be changed after consulting the manufacturer.
The following commands are supported by the reader
command-
code
function action on interface Compability with
ASB1.0
DIAG
diagnosis / state of the reader
state or error message
no
GT
read transponder (get tag)
transponder number
yes
I
NIT
load basic configuration
boot message / <CR>
yes
RST
warm start
boot message / <CR>
yes
VER
Output version number
version number
yes
VS
Output of all parameter values
List of parameters
yes
VSAVE
store current configuration
ok
yes
The parameters which can be modified are:
com-
mand-
code
function universally
defined pa-
rameters
(ASB 1.0)
valid parame-
ter values for
ARE K1
default-values
MD mode of operation 0 .. 2 0 .. 2 2 (triggered by
interface)
BD
baud rate
0 .. 3
0 .. 3
2 (19200baud)
EC
ec
ho
0, 1
0, 1
0 (off)
CN
suppression of NoRead
0, 1
0 .. 2
0 (output FFFFFFFFFF)
CID filter function for multiply read
IDs
0, 1 0, 1 0 (filter off)
NID number of identical IDs per read-
ing cycle
0 , 1 0 , 1 1 (two out of two)
NRD
superimposition of t
elegrams
0 .. 2
0 .. 2
1 (two telegrams)
QN1 digital output QN1 0 .. 2 0 .. 2 2 (controlled by reading
process)
QR1 digital output QR1 0 .. 2 0 .. 2 2 (controlled by reading
process)
TOR timeout parameter for unsuccess-
full reading
0...9 0...255 5 (500ms)
ALGO
algorithm (type of transponder)
-
0 .. 2
1 (trovan read only)
PM
type of protocol
-
0, 1
0 (ASCII-protocol)
For more details please see the manual „Command Set for ARE K1“.