User's Manual

--------------------------------------------------------------------------------25/26--------------------------------------------------------------------------------
6.3 List of error messages
error number function error-LED
#00 command code not known, wrong code no
#01 stack-error (under- / overflow) no
#02 parameter value not valid no
#03 error in EEPROM no
#04 function not supportet no
#05 reserved no
#06 reserved no
#07 reserved no
#08 reserved no
#09 kein Code gelesen (NoRead) no
#10 antenna error yes
#99 system o.k. (DIAG state messages) no
Table 6.2: List of error messages
6.4 List of system commands
command-
code
function action on interface Compability
with ASB1.0
DIAG diagnosis / state of the reader state or error message no
GT read transponder (get tag) transponder number yes
INIT load basic configuration boot message / <CR> yes
RST warm start boot message / <CR> yes
VER Output version number version number yes
VS Output of all parameter values List of parameters yes
VSAVE store current configuration ok yes
Table 6.3: List of system commands
6.5 List of parameters and default values
com-
mand-
code
function universally
defined
parameters
(ASB 1.0)
valid pa-
rameter
values for
ARE K1
default-values
MD mode of operation 0 .. 2 0 .. 2 2 (triggered by interface)
BD baud rate 0 .. 3 0 .. 3 2 (19200baud)
EC echo 0, 1 0, 1 0 (off)
CN suppression of NoRead 0, 1 0 .. 2
0 (ou
tput FFFFFFFFFF)
CID filter function for multiply read IDs 0, 1 0, 1 0 (filter off)
NID number of identical IDs per reading cycle 0 , 1 0 , 1 1 (two out of two)
NRD superimposition of telegrams 0 .. 2 0 .. 2 1 (two telegrams)
RNR reader identification number - 0 .. 9, 10..
99
0 (not active)