User's Manual
--------------------------------------------------------------------------------19/26--------------------------------------------------------------------------------
Parameter
7
Function
0 limits the reading process duration to
exactly one reading cycle
1 Tmax = 100ms
2 Tmax = 200ms
...
5 Tmax = 500ms
...
255 Tmax = 25,5s
output (example): 2 <CR>, this means 200ms.
4.17 VER
The command VER outputs the software version of the reader. The software version is permanently
stored in the program memory together with the firmware.
input format: VER <CR>
output: AEG <SP> ID <SP> - <SP> V1.4E <CR>
4.18 VS
The command VS lists all current parameter settings.
input format: VS <CR>
output (example): EC <SP> 0 <CR>
BD <SP> 2 <CR>
MD <SP> 2 <CR>
.....
4.19 VSAVE
All operating parameters temporarily stored are saved permanently using VSAVE.
input format: VSAVE <CR>
output: ok <CR> oder error message
course:
7
values > 9 are not compatible down to ASB 1.0