EPROM
set of parameter
ex work
(default values)
RAM
actual set of
parameter
INIT
Figure 4.1: function of INIT
4.9 MD
The command MD changes the operating mode.
input format: MD <SP> parameter <CR>
Parameter Function
0 continuous operation
1 externally triggered
2 triggered via serial interface
output(example): 0 <CR>
4.10 NID
NID specifies the number of identical transponder numbers, which have to appear for the result ”suc-
cessful reading” within a reading cycle. In the setting NID = 1, two successive readings have to show
the same transponder number.
input format: NID <SP> parameter <CR>
Parameter Function
0 one out of one (no effect)
1 two out of two
output (example): 1 <CR>
Sequence of readings Length of the reading
cycle
Result of the reading cycle
NoRead 1 reading NoRead
0000125ED1, 0000125ED1 2 readings 0000125ED1
0000125ED1, 0000126ED1 2 readings NoRead