Input format: BD <SP> Parameter <CR>
Parameter
value
Function
0 4800 baud
1 9600 baud
2
4
19200 baud
3 38400 baud
output (example): 2 <CR>
note: The settings are effective after a warm start using the RST command.
4.3 CID
With CID=1 only the first of in succession identical transponder numbers is output on the serial interface.
The possibly following identical transponder numbers are suppressed, as long as no new valid transponder
number is received, processed and output. NoReads do not influence the data filtering
input format: CID <SP> parameter <CR>
Parame-
ter
Function
0 no filter function
1 suppression of repeatedly read IDs
output (example): 0 <CR>
Example: A, B, C are specific different transponder numbers, N is NoRead:
Sequence of reading cycles Output sequence after
filtering with CN=0
and CID=1
Output sequence after
filtering with CN=1
and CID=1
N, N, ......,N, A, A, A, ....A, N,N, ......... N, N, ......,N, A, N, N,
.......
A
N. N, N, A, A, A, N, A, A, B, A, C, C, C, .......
N. N, N, A, N, B, A, C,
.....
A, B, A, C
N, N, B, B, B, B, B, N, N, N, B, B, B, B, N,
N,...
N, N, B, N, N, N, N,
N,...
B
N, N, N, B, B, B, B, B, N, B, B, B, B, N, N,
N, ....
N, N, N, B, N, N, N, N,
....
B
Table 4.1: example for the effect of the CID function
annotation: The internal reference number is cleared at the following conditions:
after a cold start
after a warm start