User's Manual

--------------------------------------------------------------------------------12/26--------------------------------------------------------------------------------
The transponder ID 001F37BD92 will be transmitted on the interface using the characters 30H, 30H,
31H, 46H, 33H, 37H, 42H, 44H, 39H, 32H and <CR>.
3.10.1 Output format for the NoRead information
An unsuccessful reading cycle is represented by the NoRead character sequence (see CN command in chap-
ter 4.3). Normally the NoRead is coded by the number FFFFFFFFFF, which can never appear as trans-
ponder code.
Alternativly at the ARE K1 a NoRead information can be output using the error messages <NAK> #09
<CR>. For this the parameter value of CN has to be set to 2
3
.
3.10.2 Output of a reader number
For readers connected by a network the output of an individual reader identification is necessary, to assign
a message with the belonging sender device. This identification can be made activating the RNR function
(see chapter 4.14 - reader number). If the RNR function is active, each reader answer is preceded by a
reader number and a space character as well (i.e 15 <SP>).
4 Command set specification
4.1 ALGO
Algo defines the type of chip used.
Input format: ALGO <SP> Parameter <CR>
Parameter
value
Function
1 Trovan read only
2 PSK
output (example): 1 <CR>
note: After correct parameter setting, Algo defines chip type used.
4.2 BD
The BD command enables the change of the baud rate.
3
not compatible down to ASB 1.0