4.3.3 VSAVE – Save parameter
All operating parameters temporarily stored are saved permanently using VSAVE.
Input format: VSAVE <CR>
Output: ok <CR>
4.3.4 RST – Warm start
The command RST causes a warm start of the reader.
Input format: RST <CR>
Output: If EC = 1 you get the startup message, else you get <CR>
Figure 7: Workflow RST
4.3.5 INIT – Warmstart with default parameters
This command starts the reader new with the default parameters.
Input format: INIT <CR>
Output: If EC = 1 you get the startup message, else you get <CR>
RST
system start with the actual
parameters saved in the
EEPROM
system initialization