User's Manual
--------------------------------------------------------------------------------23/48--------------------------------------------------------------------------------
5.3.7 SI – set iso standard
With this command you can switch the iso standard of the reader.
Input format: SI <SP> parameter <CR>
Output (example): 0 <CR>
Parameter:
PARAMETER FUNCTION
0 ISO 14443A
1 ISO 15693
5.3.8 VSAVE – variables save
With the command VSAVE the following parameters are saved to the internal EEPROM:
AFI
2
, KM
1
, KT
1
, MD, SI, TOR
Input format: VSAVE <CR>
Output (example): ACK <CR>
1
just available in the ISO 14443A standard
2
just available in the ISO 15693 standard
5.3.9 VS – variables show
With the command VS the reader shows the settings of the following parameters:
AFI
2
, KM
1
, KT
1
, MD, SI, TOR
Input format: VS <CR>
Output (example): ACT <SP> 14 <CR>
AM <SP> 0 <SP>
…