User's Manual
--------------------------------------------------------------------------------22/48--------------------------------------------------------------------------------
PARAMETER FUNCTION
0 No suppression
1 Suppression of equal transponder numbers
5.3.4 INIT – initialization
With the command INIT all paramters of this command set are set to the default values. After that
you can save the settings with the command VSAVE.
Input format: INIT <CR>
Output (example): ACK <CR>
5.3.5 MC – mirror code
With this command you can change the output order of the bytes from a transpondercode.
Input format: MC <CR>
Output (example): 0 <CR>
5.3.6 TOR – maximum reading time
Timeout time for the reader. TOR is used in operation mode 2 as maximum gating time for a reading
process. The length of the maximum gating time results from the equation gating_time = TOR * TB.
The time constant TB (time base) has always the default value 100ms.
Input format: TOR <SP> parameter <CR>
Output (example): 05 <CR>
Parameter:
PARAMETER FUNCTION
00h limits the reading process duration of exactly one reading cycle
01h..FFh limits the reading process duration to maximum 1..256 times
TB