User's Manual
---------------------------------------------------------------33/36-------------------------------------------------------------
7 USB Interface Configuration used in online and
database mode
The USB connection to the ARE H9 is established as an additional com port via a USB bridge
driver on the host PC. The protocol uses the RS232 specification with the settings:
19200 Baud, 8 Data bits, no party bit, one stop bit, no hardware handshake.
8 RS232 Interface Settings
**)
If the ARE H9 Rs232 is used on a PC a Rs232-Crossover (lines Rxd, Txd are crossed) is
necessary.
In Operation Mode “Database/Ser.” and “online” are the following communication settings in
use:
9600 Baud, 8 Data bits, no party bit, one stop bit, no hardware handshake.
9 Control Characters used in the online mode
character
value
hexadecimal
F
unction
<NL> 0x00 zero character, terminates text element
<STX> 0x02 start of text
<CR> 0x0D carriage return
<LF> 0x0A line feed
**)
only in Rs232 version